Related papers: First evidence of luminescence in a He/CF$_4$ gas …
The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and…
We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
For its ease manufacturing, flexible geometry, and cheap manufacturing cost, the gas electron multiplier (GEM) detector can be used as an x-ray image sensor. For this purpose, we acquired relative detection efficiencies and suggested a…
We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains,…
Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace…
A novel concept for electroluminescence (EL) structures was recently proposed. In it, a wavelength-shifting material is deposited inside the holes of GEM-like structures which, after suitable optical treatment of its electrodes, improves…
The gas electron multiplier produced with the polyimide film 100 um thick. The maximum gas gain obtained with gas mixture Ar/CH4(91/9) was 5000. No decrease of gas gain with rates up to 2\cdot10^4 1/(mm^2 s) was observed. The possibility of…
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in…
The advancement of Micro Pattern Gaseous Detector technology offers us different kinds of detectors with good spatial resolution and high rate capability and the Gas Electron Multiplier (GEM) detector is one of them. Typically GEM is made…
In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of…
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…
We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences…
With the intention of creating a complete simulation of the Thick GEM detector, this work presents a partial simulation of the interaction of 6 keV X-Ray radiation with a gas volume. For the gas, it was used pure Argon, Xenon and CO2 as…
Optical time projection chambers (OTPCs) are well suited for applications that require the highest spatial resolution for particle track reconstruction. The MIGDAL experiment uses a glass GEM-based OTPC and observes a systematic excess in…
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting…