Related papers: Development of a Negative Ion Micro TPC Detector w…
The purpose of the present paper is to study the neutrino properties as they may appear in the low energy neutrinos emitted in triton decay, with maximum neutrino energy of 18.6 KeV. The technical challenges to this end can be summarized as…
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…
The 50~kton Iron Calorimeter (ICAL) detector at the underground India based Neutrino Observatory (INO) will make measurements on atmospheric neutrinos. Muons produced in charged current (CC) interactions of muon neutrinos with the iron are…
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and…
We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…
We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with…
The Mini-SiTian project, which is the pathfinder for the SiTian project, utilizes three 30 cm telescopes equipped with commercial CMOS cameras (ZWO ASI6200MM Pro) to simulate large-area time-domain survey. Due to the avoidance of the…
Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…
Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…
We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed…
Direct Dark Matter searches are nowadays one of the most fervid research topics with many experimental efforts devoted to the search for nuclear recoils induced by the scattering of Weakly Interactive Massive Particles (WIMPs). Detectors…
A novel charged particle tracking device, a high precision time projection chamber with gas electron multiplier and pad readout, is a leading candidate as the central tracker for an experiment at the International Linear Collider. To…
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross…
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…
Dark matter (DM) detectors employing a Spherical Proportional Counter (SPC) have demonstrated a single-electron detection threshold and are projected to have small background rates. We explore the sensitivity to DM-electron scattering with…
The search for weakly interacting massive particles (WIMPs) by direct detection faces an encroaching background due to coherent neutrino-nucleus scattering. As the sensitivity of these experiments improves, the question of how to best…
This paper presents the Forward Time Projection Chamber (FTPC) system of the NA61/SHINE experiment at the CERN SPS accelerator. This TPC system applies a novel tandem-TPC design to reduce the background originating from particle tracks not…
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and…
In our quest to understand the nature of dark matter and discover its non-gravitational interactions with ordinary matter, we propose an experiment using a \pbo ~calorimeter to search for or set new limits on the production rate of i)…