English
Related papers

Related papers: Reconstruction of high-resolution 6x6-mm OCT angio…

200 papers

Optical coherence tomography angiography (OCTA) requires high transverse sampling density for visualizing retinal and choroidal capillaries. Low transverse sampling causes resolution degradation, such as the angiograms in wide-field OCTA.…

Image and Video Processing · Electrical Eng. & Systems 2020-01-09 Ting Zhou , Kang Zhou , Jianlong Yang , Liyang Fang , Yan Hu , Yitian Zhao , Jun Cheng , Xiangping Chen , Shenghua Gao , Jiang Liu

Reducing the bit-depth is an effective approach to lower the cost of optical coherence tomography (OCT) systems and increase the transmission efficiency in data acquisition and telemedicine. However, a low bit-depth will lead to the…

Image and Video Processing · Electrical Eng. & Systems 2021-02-03 Qiangjiang Hao , Kang Zhou , Jianlong Yang , Liyang Fang , Zhengjie Chai , Yuhui Ma , Yan Hu , Shenghua Gao , Jiang Liu

Optical Coherence Tomography Angiography (OCTA) has been increasingly used in the management of eye and systemic diseases in recent years. Manual or automatic analysis of blood vessel in 2D OCTA images (en face angiograms) is commonly used…

Image and Video Processing · Electrical Eng. & Systems 2021-03-01 Shuai Yu , Jianyang Xie , Jinkui Hao , Yalin Zheng , Jiong Zhang , Yan Hu , Jiang Liu , Yitian Zhao

Optical coherence tomography (OCT) captures cross-sectional data and is used for the screening, monitoring, and treatment planning of retinal diseases. Technological developments to increase the speed of acquisition often results in systems…

Image and Video Processing · Electrical Eng. & Systems 2023-01-03 Timothy T. Yu , Da Ma , Jayden Cole , Myeong Jin Ju , Mirza F. Beg , Marinko V. Sarunic

Retinal Optical Coherence Tomography Angiography (OCTA) with high-resolution is important for the quantification and analysis of retinal vasculature. However, the resolution of OCTA images is inversely proportional to the field of view at…

Image and Video Processing · Electrical Eng. & Systems 2022-07-26 Huaying Hao , Cong Xu , Dan Zhang , Qifeng Yan , Jiong Zhang , Yue Liu , Yitian Zhao

This study is to demonstrate deep learning for automated artery-vein (AV) classification in optical coherence tomography angiography (OCTA). The AV-Net, a fully convolutional network (FCN) based on modified U-shaped CNN architecture,…

Image and Video Processing · Electrical Eng. & Systems 2020-06-09 Minhaj Alam , David Le , Taeyoon Son , Jennifer I. Lim , Xincheng Yao

Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed…

Image and Video Processing · Electrical Eng. & Systems 2020-10-30 Lennart Husvogt , Stefan B. Ploner , Siyu Chen , Daniel Stromer , Julia Schottenhamml , A. Yasin Alibhai , Eric Moult , Nadia K. Waheed , James G. Fujimoto , Andreas Maier

Existing methods to reconstruct vascular structures from a computed tomography (CT) angiogram rely on injection of intravenous contrast to enhance the radio-density within the vessel lumen. However, pathological changes can be present in…

Image and Video Processing · Electrical Eng. & Systems 2020-02-11 Anirudh Chandrashekar , Ashok Handa , Natesh Shivakumar , Pierfrancesco Lapolla , Vicente Grau , Regent Lee

Optical coherence tomography angiography (OCTA) is a noninvasive imaging technique that can reveal high-resolution retinal vessels. In this work, we propose an accurate and efficient neural network for retinal vessel segmentation in OCTA…

Image and Video Processing · Electrical Eng. & Systems 2023-09-19 Haojian Ning , Chengliang Wang , Xinrun Chen , Shiying Li

Optical Coherence Tomography (OCT) is a widely used non-invasive biomedical imaging modality that can rapidly provide volumetric images of samples. Here, we present a deep learning-based image reconstruction framework that can generate…

Image and Video Processing · Electrical Eng. & Systems 2021-07-30 Yijie Zhang , Tairan Liu , Manmohan Singh , Yilin Luo , Yair Rivenson , Kirill V. Larin , Aydogan Ozcan

Optical coherence tomography angiography (OCTA) has drawn numerous attentions in ophthalmology. However, its data acquisition is time-consuming, because it is based on temporal-decorrelation principle thus requires multiple repeated…

Medical Physics · Physics 2019-10-15 Jianlong Yang , Peng Liu , Lixin Duan , Yan Hu , Jiang Liu

Optical Coherence Tomography Angiography (OCTA) is a non-invasive and non-contacting imaging technique providing visualization of microvasculature of retina and optic nerve head in human eyes in vivo. The adequate image quality of OCTA is…

Image and Video Processing · Electrical Eng. & Systems 2021-07-23 Yufei Wang , Yiqing Shen , Meng Yuan , Jing Xu , Bin Yang , Chi Liu , Wenjia Cai , Weijing Cheng , Wei Wang

Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique widely used to study vascular structures and micro-circulation dynamics in the retina and choroid. OCTA has been widely used in clinics for diagnosing…

Image and Video Processing · Electrical Eng. & Systems 2025-08-26 Kejie Chen , Guanbing Gao , Xiaochun Yang , Wenbo Wang , Jing Na

Optical Coherence Tomography Angiography (OCTA) and its derived en-face projections provide high-resolution visualization of the retinal and choroidal vasculature, which is critical for the rapid and accurate diagnosis of retinal diseases.…

Computer Vision and Pattern Recognition · Computer Science 2025-09-10 Pooya Khosravi , Kun Han , Anthony T. Wu , Arghavan Rezvani , Zexin Feng , Xiaohui Xie

Optical coherence tomography angiography (OCTA) is a new imaging modality to visualize retinal microvasculature and has been readily adopted in clinics. High-resolution OCT angiograms are important to qualitatively and quantitatively…

Image and Video Processing · Electrical Eng. & Systems 2023-05-11 Yuyan Ruan , Dawei Yang , Ziqi Tang , An Ran Ran , Carol Y. Cheung , Hao Chen

Conventional Fourier-domain Optical Coherence Tomography (FD-OCT) systems depend on resampling into wavenumber (k) domain to extract the depth profile. This either necessitates additional hardware resources or amplifies the existing…

Optics · Physics 2025-09-24 Maryam Viqar , Erdem Sahin , Elena Stoykova , Violeta Madjarova

Optical coherence tomography angiography (OCTA) is a novel non-invasive imaging modality for the visualisation of microvasculature in vivo that has encountered broad adoption in retinal research. OCTA potential in the assessment of…

Image and Video Processing · Electrical Eng. & Systems 2020-06-02 Ylenia Giarratano , Eleonora Bianchi , Calum Gray , Andrew Morris , Tom MacGillivray , Baljean Dhillon , Miguel O. Bernabeu

Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that can acquire high-resolution volumes of the retinal vasculature and aid the diagnosis of ocular, neurological and cardiac diseases. Segmenting the…

Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that extends the functionality of OCT by extracting moving red blood cell signals from surrounding static biological tissues. OCTA has emerged as a valuable…

Image and Video Processing · Electrical Eng. & Systems 2023-05-04 Jinpeng Liao , Tianyu Zhang , Yilong Zhang , Chunhui Li , Zhihong Huang

X-ray coronary angiography (XCA) is used to assess coronary artery disease and provides valuable information on lesion morphology and severity. However, XCA images are 2D and therefore limit visualisation of the vessel. 3D reconstruction of…

Image and Video Processing · Electrical Eng. & Systems 2023-03-01 Kit Mills Bransby , Vincenzo Tufaro , Murat Cap , Greg Slabaugh , Christos Bourantas , Qianni Zhang
‹ Prev 1 2 3 10 Next ›