English
Related papers

Related papers: Time performance of a triple-GEM detector at high …

200 papers

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…

Instrumentation and Detectors · Physics 2026-05-29 Sachin Rana , Md. Kaosor Ali Mondal , Poojan Angiras , Amal Sarkar

Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…

High Energy Physics - Experiment · Physics 2024-01-23 S. Mandal , S. Chatterjee , A. Sen , S. Gope , S. Dhani , A. C. Hegde , M. Chatterjee , S. Das , S. Biswas

Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…

High Energy Physics - Experiment · Physics 2025-05-07 S. Mandal , S. Gope , S. Das , S. Biswas

A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…

In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…

Instrumentation and Detectors · Physics 2020-09-07 Gábor Galgóczi , Gergő Hamar , Péter Pázmándi , Dezső Varga

The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…

Instrumentation and Detectors · Physics 2021-05-26 Promita Roy , Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar

Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…

Instrumentation and Detectors · Physics 2023-05-17 S. Chatterjee , A. Sen , R. Paul , S. Sahai , S. Das , S. Biswas

The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…

Instrumentation and Detectors · Physics 2022-12-21 Antonello Pellecchia , Piet Verwilligen

The performance of triple-GEM detectors in He+N2 gas mixtures is studied in the range of 1-10 atm. The results obtained are relevant in the field of minimization of ionic space-charge effect in the TPC and neutron detection.

Instrumentation and Detectors · Physics 2007-05-23 A. Bondar , A. Buzulutskov , L. Shekhtman , A. Vasiljev

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…

Instrumentation and Detectors · Physics 2013-02-14 M. Poli Lener , M. Bazzi , G. Corradi , C. Curceanu , A. D'Uffizi , C. Paglia , A. Romero Vidal , E. Sbardella , A. Scordo , D. Tagnani , J. Zmeskal

The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not…

Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…

Instrumentation and Detectors · Physics 2018-08-15 Rajendra Nath Patra , Rama N. Singaraju , Saikat Biswas , Zubayer Ahammed , Tapan K. Nayak , Yogendra P. Viyogi

Performance of triple GEM prototypes has been evaluated by means of a muon beam at the H4 line of the SPS test area at CERN. The data from two planar prototypes have been reconstructed and analyzed offline with two clusterization methods:…

The Gas Electron Multiplier (GEM) detector is one of the advanced members of the Micro Pattern Gas Detector (MPGD) family, used in High Energy Physics (HEP) experiments as a tracking device due to its high rate handling capability and good…

Instrumentation and Detectors · Physics 2022-06-23 S. Chatterjee , A. Sen , S. Das , S. Biswas

Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge…

Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly…

Instrumentation and Detectors · Physics 2008-11-26 Maxim Titov
‹ Prev 1 2 3 10 Next ›