Related papers: Precision efficiency calibration of a high-purity …
To build upon the goals of the upcoming INTEGRAL mission, the next generation soft gamma-ray (0.2-20 MeV) observatory will require improved sensitivity to nuclear line emission while maintaining high spectral resolution. We present the…
Quantum technologies with quantum correlated light require photodiodes with near-perfect `true' quantum efficiency, the definition of which adequately accounts for the photodiode dark noise. Future squeezed-light-enhanced gravitational wave…
Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…
The photon detection efficiencies of multi-pixel Geiger-mode avalanche photodiodes manufactured by different produ cers are estimated. A new fit method of the response spectra to low-intensity light, taking into ac count after-pulse and…
A search of axions produced in nuclear transitions was performed at the Kuo-Sheng Nuclear Power Station with a high-purity germanium detector of mass 1.06 kg at a distance of 28 m from the 2.9 GW reactor core. The expected experimental…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done…
The CONUS+ experiment has recently reported the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) of reactor antineutrinos on germanium nuclei and is now entering a precision phase. The dominant uncertainty in the…
Gallium solar neutrino experiments have historically used radiochemical counting to determine the event rate. A detector which directly measures the ejected electron and de-excitation gamma could reduce background counting rates by way of a…
The GERmanium Detector Array (GERDA) experiment located at the INFN Gran Sasso Laboratory (Italy), is looking for the neutrinoless double beta decay of Ge76, by using high-purity germanium detectors made from isotopically enriched material.…
Two germanium detectors are currently operating in the Canfranc Underground Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX detector (RG-2) which has an energy threshold of 4 keV and a low-energy background…
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few…
The understanding of the instrumental response of the GLAST Burst Monitor BGO detectors at energies above the energy range which is accessible by common laboratory radiation sources (< 4.43 MeV), is important, especially for the later…
We present in this paper the results of a comprehensive GEANT simulation of the Gamma-Ray Imaging Detector (GRID) being developed for the AGILE space astrophysics mission. The GRID is designed to be sensitive in the 30 MeV - 50 GeV energy…
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known…
The Gamma-Ray Energy Tracking Array (GRETA) is a next-generation gamma-ray spectrometer designed to push the frontiers of nuclear structure and astrophysics experiment. Its high sensitivity is enabled by high-precision localization of…
The full-energy-peak efficiency of HPGe detectors at $\gamma$-ray energies around 10 MeV is not easily accessible with experimental methods. Monte-Carlo simulations with Geant4 can provide these efficiencies. G4Horus is a ready-to-use…
We describe the results of detailed 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. Several astrophysics applications require the detection of photons in the energy…
We performed an analysis of coherence properties of the 4-th generation high-energy storage rings with emittance values of 10 pmrad. It is presently expected that a storage ring with these low emittance values will reach diffraction limit…
A small, natural abundance, germanium detector (COSME) has been operating recently at the Canfranc Underground Laboratory (Spanish Pyrenees) in improved conditions of shielding and overburden with respect to a previous operation of the same…