Related papers: Energy resolution and linearity of XENON1T in the …
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time…
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$…
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to…
Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the…
Several efforts are ongoing for the development of spherical gaseous time projection chamber detectors for the observation of rare phenomena such as weakly interacting massive particles or neutrino interactions. The proposed detector,…
We present results on the search for double-electron capture ($2\nu\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$\beta$ decay ($0\nu\beta\beta$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the…
NEXT is a high-pressure (10-15 bar) xenon Time Projection Chamber dedicated to neutrinoless double beta decay searches. NEXT-DEMO is a large prototype of the NEXT experiment, constructed to demonstrate the feasibility of the NEXT detector…
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei.…
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection…
The NEXT-100 detector will search for the neutrinoless double beta decay of $^{136}$Xe using an electroluminescent high-pressure xenon gas TPC filled with 100 kg of enriched Xe. An observation of this hypothetical process would establish a…
This work aims to present the current state of simulations of electroluminescence (EL) produced in gas-based detectors with special interest for NEXT --- Neutrino Experiment with a Xenon TPC. NEXT is a neutrinoless double beta decay…
We investigate the detection prospects for two-neutrino and neutrinoless second order weak decays of $^{124}$Xe -- double electron capture ($0/2\nu\text{ECEC}$), electron capture with positron emission ($0/2\nu\text{EC}\beta^+$) and…
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at…
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30)…
AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…
The next-generation of $0\nu\beta\beta$ searches are targeting half-life sensitivities towards 10$^{27}$--10$^{28}$ years. Gaseous xenon time projection chamber (GXeTPC) detectors may be able to meet this challenge due to their excellent…
The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…
A high pressure xenon gas time projection chamber with electroluminescent amplification (EL HPGXe TPC) searching for the neutrinoless double beta ($0\nu\beta\beta$) decay offers: excellent energy resolution ($0.5-0.7\%$ FWHM at the…
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment.…