Related papers: Background in the CMS muon detectors: simulation a…
The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the…
The CMS muon system is undergoing substantial upgrades to meet the challenges of the High-Luminosity LHC (HL-LHC), including the installation of the new Muon Endcap 0 (ME0) detector. Large-scale production started in 2024. ME0 is a…
The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause…
Simulations for the 125-GeV Higgs Factory (HF) Muon Collider (MC) have shown large background particle loads on the collider detector. To verify level, source and composition of background calculations were performed using FLUKA and MARS…
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost…
Physics at a multi-TeV muon collider needs a change of perspective for the detector design due to the large amount of background induced by muon beam decays. Preliminary studies, based on simulated data, on the composition and the…
CMS has developed a fast detector simulation package, which serves as a fast and reliable alternative to the detailed GEANT4-based (full) simulation, and enables efficient simulation of large numbers of standard model and new physics…
After a brief overview of the Compact Muon Solenoid (CMS) experiment, the status of construction, installation and commissioning is described. Very good progress has been achieved in the past year. Though many significant challenges still…
As part of the Phase II upgrade program, the Compact Muon Solenoid (CMS) detector will incorporate a new timing layer designed to measure minimum ionizing particles (MIPs) with a time resolution of $\sim$30 ps. Precision timing will…
Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the…
The CMS experiment recorded 177.75 /fb of proton-proton collision data during the RUN-1 and RUN-2 data taking period. Successful data taking at increasing instantaneous luminosities with the evolving detector configuration was a big…
In the framework of the High Luminosity LHC upgrade program, the CMS muon group built several different RPC prototypes that are now under test at the new CERN Gamma Irradiation Facility (GIF++). A dedicated Detector Control System has been…
A full replacement of the existing muon trigger system in the CMS (Compact Muon Solenoid) detector is planned for operating at the maximum instantaneous luminosities of about $5-7.5\times10^{34}$ cm$^{-2}$ s$^{-1}$ expected in HL-LHC (High…
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…
A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or…
The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40…
Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which…
After the Large Hadron Collider (LHC) upgrade into High Luminosity LHC (HL-LHC), the instantaneous luminosity is expected to reach values up to 7.5x10^34cm^2/s, causing a harsher radiation environment as well as a significant increase in…
The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…
Muons from cosmic-ray interactions in the atmosphere provide a high-statistics source of particles that can be used to study the performance and calibration of the ATLAS detector. Cosmic-ray muons can penetrate to the cavern and deposit…