Related papers: Optimization of LANSCE Proton Beam Performance for…
There is great need for high intensity proton beams from compact particle accelerators in particle physics, medical isotope production, and materials- and energy-research. To address this need, we present, for the first time, a design for a…
The High Intensity Proton Accelerator (HIPA) cyclotron at the Paul Scherrer Institut (PSI) delivers 590 MeV CW proton beam with a maximum power of 1.42 MW. After extraction, the beam is transferred in a 120 m long channel towards two target…
A microwave ion source is used as an ion source of 100-MeV proton accelerator at Korea Multipurpose Accelerator Complex (KOMAC). The specifications of the ion source are 50 keV in energy and 20 mA in peak current. The plasma is operated in…
Using the China Spallation Neutron Source (CSNS) linac as the injector, a 500 MeV proton synchrotron is proposed for multidisciplinary application, such as biology, material and proton therapy. The synchrotron will deliver proton beam with…
A 5-MeV RFQ designed for a proton current up to 100-mA CW is now under construction as part of the High Intensity Proton Injector project (IPHI). Its computed transmission is greater than 99 %. The main goals of the project are to verify…
An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is…
Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static…
Proton beams with up to 100 pC bunch charge, 0.48 MeV cut-off energy and divergence as low as a $3^{\circ}$ were generated from solid targets at kHz repetition rate by a few-mJ femtosecond laser under controlled plasma conditions. The beam…
The proton irradiation accelerator is widely founded for industry application, and should be designed as compact, reliable, and easy operate. A 10 MeV proton beam is designed to be injected into the slow circulation ring with the repetition…
To maximize the physics potential of future neutrino oscillation experiments, it is proposed to build a 15-MW `proton driver' consisitng solely of a 3-GeV proton injector linac (PI) and a 17-GeV superconducting ILC-type linac (SCL). The…
The intense beam-beam effect at the interaction point of the International Linear Collider (ILC) causes large disruption of the beams and the production of photons. These photons, arising dominantly through beamstrahlung emission, are…
Suppression of beam losses is essential for successful operation of high-intensity linac. Historically, the values of the field amplitudes and phases of the side-coupled, 805-MHz LANSCE linac modules are maintained using a well-known…
A possible solution to realize a conventional positron source driven by a several-GeV electron beam for the International Linear Collider is proposed. A 300 Hz electron linac is employed to create positrons with stretching pulse length in…
The paper reports the results of two-dimensional particle-in-cell simulations of proton beam acceleration at the interactions of a 130 fs laser pulse of intensity from the range of 10^21-10^23 W/cm^2, predicted for the Extreme Light…
The article considers an opportunity of simultaneous pulsed acceleration of seven proton beams with current one hundred milliamps in each beam. The accelerator consists of two parts. In the first part of the accelerator having the length…
Cerium-134 is an isotope desired for applications as a chemical analogue to the promising therapeutic radionuclide $^{225}$Ac, for use in bio-distribution assays as an in vivo generator of the short-lived positron-emitting isotope…
We have measured the production rates and production cross sections for a variety of radioactive isotopes which were produced from 124Xe, 48Ca, and 238U beams at an energy of 345 MeV/nucleon using the BigRIPS separator at the RIKEN Nishina…
The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…
The IsoDAR collaboration is developing a high-current cyclotron for a neutrino search experiment. Designed to deliver 10 mA of 60 MeV protons, the current and power of this cyclotron far exceed those of existing accelerators, opening new…
Proton (and ion) cancer therapy has proven to be an extremely effective even supe-rior method of treatment for some tumors 1-4. A major problem, however, lies in the cost of the particle accelerator facilities; high procurement costs…