Related papers: Electromagnetic Calorimeter for MPD Spectrometer a…
A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…
The CMS Zero Degree Calorimeters, ZDCs, will measure photons and neutrons emitted with |eta|> 8.6 from Pb+Pb, p+Pb and p+p collisions at sqrt(Snn)=5.5, 8.8 and 14 TeV respectively. The calorimeter consists of an electromagnetic part…
We describe the design concept and estimated performance of an iron-scintillator sampling calorimeter for the future Electron Ion Collider. The novel aspect of this detector is a multi-dimensional readout coupled with foreseen excellent…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with…
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is…
The Multipurpose Detector (MPD) consists of a typical array of sub-detectors to study the nuclear matter originating from the collisions of beams provided by the Nuclotron-based Ion Collider fAcility (NICA). A beam monitoring…
India-based Neutrino Observatory (INO) is a planned neutrino experiment to be build up in southern part of India.The INO observatory will host a 51 kton Iron Calorimeter (ICAL) detector to detect atmospheric neutrinos. Resistive Plate…
Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine…
The proposed new Electron-Ion Collider poses a technical and intellectual challenge for the detector design to accommodate the long-term diverse physics goals envisaged by the program. This requires a 4{\pi} detector system capable of…
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the…
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of…
While the CMS experiment is currently harvesting LHC collision data at CERN, the performance of its electromagnetic calorimeter (ECAL) is being constantly monitored, and work has started to assess the need for changes to the detector to…
Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
A new project of Nuclotron-based Ion Collider fAcility (NICA) and Multi-Purpose Detector (MPD) is proposed at JINR (Dubna). Status of this NICA/MPD project is outlined. Main system parameters and some construction details are given.
The CMS electromagnetic calorimeter (ECAL) is a high-resolution, hermetic, and homogeneous calorimeter made of 75,848 scintillating lead tungstate crystals. Following the discovery of the Higgs boson, the CMS ECAL is at the forefront of…
Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art…
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The…
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…