The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an…

In this work, a combination of cathode retraction and two-slit emittance measurement technique is proposed as an advanced means to individually modify emittance growth components, specifically, rf injector fringe fields, to isolate and…

Accelerator Physics · Physics 2024-09-06 Benjamin Sims , John W. Lewellen , Xu Ting , Sergey V. Baryshev

Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there…

We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (greater than or equal to 100 pC) beams produced in the DC gun-based Cornell Energy Recovery Linac Photoinjector. In…

Accelerator Physics · Physics 2015-06-23 Colwyn Gulliford , Adam Bartnik , Ivan Bazarov , Bruce Dunham , Luca Cultrera

We describe a method that uses Optical Transition Radiation (OTR) screens to measure in a single shot the emittance of an electron beam with an energy greater than 100 MeV. Our setup consists of 4 OTR screens located near a beam waist. A…

Accelerator Physics · Physics 2015-03-17 Nicolas Delerue , Riccardo Bartolini , Cyrille Thomas

Thermal emittance measurements of a CsK2Sb photocathode at several laser wavelengths are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. The thermal emittance is 0.56+/-0.03…

The production of electron bunches with low transverse emittance approaches the thermal emittance of the photocathode as various aberrations are corrected. Recently, the coupled transverse dynamics aberration was theoretically identified as…

In order to investigate and understand the influence of gun design, cathode preparation and operational parameters on the beam quality it is important to have reliable and accurate beam diagnostics available. The focus of this work was thus…

Accelerator Physics · Physics 2013-07-15 Martin Anton Helmut Schmeißer

The solenoid scan is one of the most common methods for the in-situ measurement of the thermal emittance of a photocathode in an rf photoinjector. The fringe field of the solenoid overlaps with the gun rf field in quite a number of…

Accelerator Physics · Physics 2022-01-05 Lianmin Zheng , Yingchao Du , Pengwei Huang

We present a clear signature of the Schottky effect in a RF photoinjector using photons with energy lower than the Mg cathode work function. This signature is manifested by the shift in the RF phase angle for the onset of the detection of…

Accelerator Physics · Physics 2009-11-10 Zikri M. Yusof , Manoel E. Conde , Wei Gai

Reducing the intrinsic emittance of photocathodes is one of the most promising routes to improving the brightness of electron sources. However, when emittance growth occurs during beam transport (for example, due to space-charge), it is…

Photoinjectors are the main high brightness electron sources for X-ray free electron lasers (XFEL). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It's well…

The heating of the electronic distribution of a copper photocathode due to an intense drive laser pulse is calculated under the two-temperature model using fluences and pulse lengths typical in RF photoinjector operation. Using the finite…

Accelerator Physics · Physics 2018-03-14 J. Maxson , P. Musumeci , L. Cultrera , S. Karkare , H. Padmore

Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for…

In its normal mode of operation the Argonne Wakefield Accelerator Facility uses a high charge (10-100 nC), short pulse (3-5 psec) drive bunch to excite high-gradient accelerating fields in various slow-wave structures. To generate this…

Accelerator Physics · Physics 2009-04-17 J. G. Power , H. Wang , M. E. Conde , W. Gai , R. Konecny , W. Liu , Z. Yusof

In photo injectors, the transverse emittance is one of the key measures of beam quality as it defines the possible performance of the whole facility. As such it is important to measure the emittance in photo injectors and ensure the…

Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and…

Accelerator Physics · Physics 2016-11-29 David H. Dowell

We have fabricated a custom cryogenic Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuit that has a higher measurement bandwidth compared with conventional room temperature electronics. This allowed implementing single shot…

Undesirable electron field emission (a.k.a. dark current) in high gradient RF photocathode guns deteriorates the quality of photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a…

The water Cherenkov detector array (WCDA) for the large high altitude air shower observatory(LHAASO) will employ more than 3600 hemisphere 8 inch photomultiplier tubes (PMT). The good time performance of PMT, especially the transit time…

Instrumentation and Detectors · Physics 2014-09-05 W. P. Huang , Z. B. Tang , C. Li , K. Jiang , X. K. Zhao