English
Related papers

Related papers: Material decomposition from a single x-ray project…

200 papers

X-ray dark-field imaging creates a representation of the sample where contrast is generated by subresolution features within the volume under inspection. These are detected by a local measurement of the radiation field's angular…

X-ray phase contrast imaging offers a way to visualize the internal structures of an object without the need to deposit any radiation, and thereby alleviate the main concern in x-ray diagnostic imaging procedures today. Grating-based…

X-ray dark-field imaging visualises scattering from sample microstructure, and has found application in medical and security contexts. While most X-ray dark-field imaging techniques rely on masks, gratings, or crystals, recent work on the…

The use of coherent x-ray beams has been greatly developing for the past decades. They are now used by a wide scientific community to study biological materials, phase transitions in crystalline materials, soft matter, magnetism, strained…

Materials Science · Physics 2010-09-01 V. L. R. Jacques , S. Ravy , D. Le Bolloc'h , E. Pinsolle , M. Sauvage-Simkin , F. Livet

We develop a speckle-tracking method for x-ray phase-contrast imaging, based on the concept of geometric flow. This flow is a conserved current associated with deformation of illuminating x-ray speckles induced by passage through a sample.…

Medical Physics · Physics 2018-11-14 David M. Paganin , Helene Labriet , Emmanuel Brun , Sebastien Berujon

Single-shot ptychography is a quantitative phase imaging method wherein overlapping beams of light arranged in a grid pattern simultaneously illuminate a sample, allowing a full ptychographic dataset to be collected in a single shot. It is…

Material decomposition for imaging multiple contrast agents in a single acquisition has been made possible by spectral CT: a modality which incorporates multiple photon energy spectral sensitivities into a single data collection. This work…

Medical Physics · Physics 2020-08-11 Matthew Tivnan , Steven Tilley , J. Webster Stayman

X-ray phase-contrast imaging can provide greatly improved contrast over conventional absorption-based imaging for weakly absorbing samples, such as biological soft tissues and fibre composites. In this manuscript, we introduce an easy and…

Software Engineering · Computer Science 2015-04-21 Shenghao Wang , Huajie Han , Kun Gao , Zhili Wang , Can Zhang , Meng Yang , Zhao Wu , Augusto Marcelli , Ziyu Wu

X-ray grating interferometry is an excellent technique for X-ray phase contrast imaging and X-ray wavefront sensing with applications in materials science, biology and medical diagnosis. Among other requirements, the method depends on the…

X-ray phase-contrast imaging has experienced rapid development over the last few decades, and in this technology, the phase modulation strategy of phase-stepping is used most widely to measure the sample's phase signal. However, because of…

Medical Physics · Physics 2017-12-06 Faiz Wali , Shenghao Wang , Huajie Han , Kun Gao , Zhao Wu , Peiping Zhu , Yangchao Tiana

X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating…

In this paper, a new phase-retrieval algorithm from an X-ray schlieren image is proposed. The schlieren method allows phase-contrast imaging with an objective lens and a knife-edge filter placed at the back focal plane of the objective.…

Sensitive to scattering from unresolved sample structures, the dark-field channel in full-field X-ray imaging provides complementary information to that offered by conventional attenuation and phase-contrast methods. A range of experimental…

X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research.…

The values of the signal-to-noise ratio are determined, at which the method of processing X-ray diffraction data reveals reflections with intensity less than the noise component of the background. The possibilities of the method are…

Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not…

A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real…

Medical Physics · Physics 2021-11-16 T. E. Gureyev , D. M. Paganin , B. Arhatari , S. T. Taba , S. Lewis , P. C. Brennan , H. M. Quiney

We propose a one-shot thickness measurement method for sponge-like structures using a propagation-based X-ray phase-contrast imaging (P-PCI) method. In P-PCI, the air-material interface refracts the incident X-ray. Refracted many times…

Medical Physics · Physics 2015-04-27 Yan Xi , Rongbiao Tang , Jingchen Ma , Jun Zhao

Dual-energy X-ray Computed Tomography (DECT) constitutes an advanced technology which enables automatic decomposition of materials in clinical images without manual segmentation using the dependency of the X-ray linear attenuation with…

Image and Video Processing · Electrical Eng. & Systems 2025-07-25 Hang Xu , Alexandre Bousse , Alessandro Perelli

X-ray phase-contrast imaging has the potential to improve image contrast with lower dose by probing an object's refractive properties as well as its absorptive properties. To reconstruct a phase-contrast image from a raw dataset, a phase…

Medical Physics · Physics 2025-08-19 Giavanna Jadick , Patrick La Rivière