English
Related papers

Related papers: Using precision timing to improve particle trackin…

200 papers

A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…

Low threshold detectors with single-electron excitation sensitivity to nuclear recoil events in solid-state detectors are also sensitive to the crystalline structure of the target and, therefore, to the recoil direction via the anisotropic…

High Energy Physics - Phenomenology · Physics 2023-01-18 Abolfazl Dinmohammadi , Matti Heikinheimo , Nader Mirabolfathi , Kai Nordlund , Hossein Safari , Sebastian Sassi , Kimmo Tuominen

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

The e+e- linear collider physics programme sets highly demanding requirements on the accurate determination of charged particle trajectories close to their production point. A new generation of Vertex Trackers, based on different…

High Energy Physics - Experiment · Physics 2007-05-23 Marco Battaglia , Massimo Caccia

Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly…

The ZEUS Central Tracking Detector utilizes a time difference measurement to provide a fast determination of the z-coordinate of each hit. The z-by-timing measurement is achieved by using a Time-to-Amplitude Converter which has an intrinsic…

Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…

Instrumentation and Detectors · Physics 2020-06-24 Edoardo Bossini

Microparticles ranging from sub-microns to millimeter in size are a common form of matter in magnetic fusion environment, and they are highly mobile due to their small mass. Different forces in addition to gravity can affect their motion…

Instrumentation and Detectors · Physics 2018-08-01 Pinghan Chu , Bradley T. Wolfe , Zhehui Wang

Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…

The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…

We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not…

We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can…

Recent detector concepts at future linear or circular $e^- e^+$ colliders emphasize the benefits of time-of-flight measurements for particle identification of long-lived charged hadrons. That method relies on a precise estimation of the…

Instrumentation and Detectors · Physics 2021-09-16 Winfried A. Mitaroff

We propose a new scintillator-based tracker concept based on a monolithic plastic scintillator plate with embedded scatterers and wavelength-shifting fiber readout. The embedded scatterers localize scintillation light so that channels…

Instrumentation and Detectors · Physics 2026-04-06 Naoki Otani , Seungho Han , Shun Ito , Tatsuya Kikawa , Tsuyoshi Nakaya , Mihiro Suzuki , Atsushi Tokiyasu

Abstract: Solid state sensors having timing capabilities are becoming an absolute need in particle tracking techniques of future experiments at colliders. In this sense, silicon sensors having 3D structure are becoming an interesting…

Instrumentation and Detectors · Physics 2021-03-24 Angelo Loi , Andrea Contu , Adriano Lai

The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…

High Energy Physics - Experiment · Physics 2007-05-23 E. C. Aschenauer , J. Baehr , V. Gapienko , B. Hoffmann , A. Kharchilava , H. Luedecke , R. Nahnhauer , R. Shanidze

4H-Silicon Carbide, when considered as a material for the fabrication of Low Gain Avalanche Detectors for particle timing and position measurement, offers potential advantages over Silicon. We discuss an ongoing study of this material aimed…

Instrumentation and Detectors · Physics 2022-03-17 P. Barletta , M. Cerullo , C. Haber , S. E. Holland , J. Muth , B. Sekely

Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , A. Di Mauro , M. Giliberti , A. Liguori , L. Lorusso , E. Nappi , N. Nicassio , G. Panzarini , R. Pillera , G. Volpe

The geometric-mean method is often used to estimate the spatial resolution of a position-sensitive detector probed by tracks. It calculates the resolution solely from measured track data without using a detailed tracking simulation and…

Data Analysis, Statistics and Probability · Physics 2016-07-13 Aiwu Zhang , Marcus Hohlmann

The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration