English
Related papers

Related papers: Studies on tetrafluoropropene-based gas mixtures w…

200 papers

The muon identification system of the ALICE experiment at the CERN LHC is based on Resistive Plate Chamber (RPC) detectors. These RPCs are operated in the so-called maxi-avalanche mode with a gas mixture made of tetrafluoroethane…

Instrumentation and Detectors · Physics 2020-01-29 A. Bianchi , S. Delsanto , P. Dupieux , A. Ferretti , M. Gagliardi , B. Joly , S. P. Manen , M. Marchisone , L. Micheletti , A. Rosano , E. Vercellin

Resistive Plate Chambers (RPC) have shown stable operation at the Large Hadron Collider and satisfactory efficiency for the entire Run 1 (2010-2013) and Run 2 (2015-2018) with C$_{2}$H$_{2}$F$_{4}$-based gas mixtures and the addition of…

Due to their simplicity and comparatively low cost, Resistive Plate Chambers are gaseous detectors widely used in high-energy and cosmic rays physics, when large detection areas are needed. However, the best gaseous mixtures are currently…

Instrumentation and Detectors · Physics 2022-03-01 Livia Terlizzi

The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This report shows results of…

Instrumentation and Detectors · Physics 2015-05-08 L. Benussi , S. Bianco , M. Ferrini , L. Passamonti , D. Pierluigi , D. Piccolo , A. Russo , G. Saviano

Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems of the LHC experiments will be most probably phased out of…

Instrumentation and Detectors · Physics 2016-09-21 M. Abbrescia , L. Benussi , S. Bianco , M. Ferrini , S. Muhammad , L. Passamonti , D. Pierluigi , D. Piccolo , F. Primavera , A. Russo , G. Saviano

Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC…

Instrumentation and Detectors · Physics 2020-01-29 Antonio Bianchi

The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In…

Due to their simplicity and comparatively low cost Resistive Plate Chambers are gaseous detectors widely used in high-energy and cosmic rays physics when large detection areas are needed. However, the best gaseous mixtures are currently…

Instrumentation and Detectors · Physics 2022-09-07 Alessandro Ferretti

Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…

Resistive Plate Chamber detectors are largely used in current High Energy Physics experiments, typically operated in avalanche mode with large fractions of Tetrafluoroethane (C2H2F4), a gas recently banned by the European Union due to its…

Instrumentation and Detectors · Physics 2024-10-16 Luca Quaglia

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

Instrumentation and Detectors · Physics 2025-10-08 D. Ahmadi , M. Tytgat

In recent years, there has been growing interest in tetrafluoropropene HFO1234ze(E) (C$_{3}$H$_{2}$F$_{4}$) for Resistive Plate Chambers (RPCs). This novel gas is considered a promising alternative to the standard mixtures currently used in…

Plasma Physics · Physics 2024-03-12 Antonio Bianchi , Alessandro Ferretti , Martino Gagliardi , Ermanno Vercellin

The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union…

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…

Instrumentation and Detectors · Physics 2025-03-10 Giorgia Proto

The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing $\rm C_2F_4H_2$ and in some cases $\rm…

Instrumentation and Detectors · Physics 2020-01-29 Baek Yongwook , Kim Do-won , Park Woosung , Williams Crispin , Zuyeuski Roman

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams
‹ Prev 1 2 3 10 Next ›