Related papers: First demonstration of OH suppression in a high ef…
We calculate the advances in near-infrared astronomy made possible through the use of fibre Bragg gratings to selectively remove hydroxyl emission lines from the night sky spectrum. Fibre Bragg gratings should remove OH lines at high…
Fibre Bragg grating (FBG) OH suppression is capable of greatly reducing the bright sky background seen by near infrared spectrographs. By filtering out the airglow emission lines at high resolution before the light enters the spectrograph…
PRAXIS is a second generation instrument that follows on from GNOSIS, which was the first instrument using fibre Bragg gratings for OH background suppression. The Bragg gratings reflect the NIR OH lines while being transparent to light…
The background noise between 1 and 1.8 microns in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between 1.47…
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS was…
We analyse the near-infrared interline sky background, OH and O2 emission in 19 hours of H band observations with the GNOSIS OH suppression unit and the IRIS2 spectrograph at the 3.9-m AAT. We find that the temporal behaviour of OH emission…
The sky subtraction performances of multi-fiber spectrographs are discussed, analysing in detail the case of the OPTOPUS system at the 3.6 meter ESO telescope at La Silla. A standard technique, based on flat-fields obtained with a uniformly…
Precision optical filters are key components for current and future photonic technologies. Here, we demonstrate a low loss spectral filter consisting of an ultrasteep bandpass feature with a maximum gradient of (90.6$\pm$0.7) dB/GHz,…
Ground-based observations at near-infrared wavelengths are severely affected by atmospheric OH bands. Many authors have recognized the potential gains in sensitivity from suppressing these features. Dispersive instruments show some promise…
Multi-channel aperiodic fiber Bragg grating (FBG) based hydroxyl (OH) line filters have attracted significant interest in ground-based near-infrared (NIR) astronomical observations. In this paper, we present the performance of a new…
Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH)…
We present the concept and preliminary design of the Galileo OH Subtracted Spectrograph [GOHSS], a multifibre NIR spectrograph for faint objects. The instrument represents a collaboration between the Institute of Astronomy, Cambridge and…
This paper describes an OH-airglow Suppressor (OHS) for the infrared Nasmyth focus of the Subaru telescope. OHS has the capability of eliminating 224 airglow-lines in the $J$- and $H$-bands, which are major sources of background radiation…
Massively multiplexed spectroscopic stellar surveys such as MSE present enormous challenges in the spectrograph design. The combination of high multiplex, large telescope aperture, high resolution (R~40,000) and natural seeing implies that…
Fibre-fed spectrographs now have throughputs equivalent to slit spectrographs. However, the sky subtraction accuracy that can be reached has often been pinpointed as one of the major issues associated with the use of fibres. Using technical…
OSIRIS is a near-infrared integral field spectrograph operating behind the adaptive optics system at W. M. Keck Observatory. While OSIRIS has been a scientifically productive instrument to date, its sensitivity has been limited by a grating…
We report the design and characterization of a high performance integrated arbitrary filter from 1450 nm to 1640 nm. The filter's target spectrum is chosen to suppress the night-sky OH emission lines, which is critical for ground-based…
We describe techniques concerning wavelength calibration and sky subtraction to maximise the scientific utility of data from tunable filter instruments. While we specifically address data from the Optical System for Imaging and low…
The large transparency window of silicon, covering the 1.1 um 8 um wavelength range, makes it a promising platform for the implementation of photothermal-based absorption spectrometers. These devices indirectly sense absorption in the…
I present a technique to remove the residual OH airglow emission from near infrared spectra. Historically, the need to subtract out the strong and variable OH airglow emission lines from 1-2.5um spectra has imposed severe restrictions on…