English
Related papers

Related papers: R&D for the CLIC Vertex and Tracking detectors

200 papers

Purpose: CMOS pixel sensors have become extremely attractive for future high performance tracking devices. Initial R\&D work has been conducted for the vertex detector for the proposed Circular Electron Positron Collider that will allow…

Instrumentation and Detectors · Physics 2019-09-04 L. J. Chen , H. B. Zhu , X. C. Ai , M. Fu , R. Kiuchi , Y. Liu , Z. A. Liu , X. C. Lou , Y. P. Lu , Q. Ouyang , X. Shi , J. Tao , K. Wang , N. Wang , C. F. Yang , Y. Zhang , Y. Zhou

The development of CMOS pixel sensors with column parallel read-out and integrated zero-suppression has resulted in a full size, nearly 1 Megapixel, prototype with ~100 \mu s read-out time. Its performances are quite close to the ILD vertex…

Instrumentation and Detectors · Physics 2010-07-16 Christine Hu-Guo , IPHC Collaboration , IRFU Collaboration

The Compact Linear Collider (CLIC) is a concept for a future $e^{+}e^{-}$ linear collider with a center-of-mass energy of up to 3 TeV. The design of a CLIC experiment is driven by the requirements related to the physics goals, as well as by…

Instrumentation and Detectors · Physics 2014-02-13 Christian Grefe

CMOS pixel sensors (CPS) represent a novel technological approach to building charged particle detectors. CMOS processes allow to integrate a sensing volume and readout electronics in a single silicon die allowing to build sensors with a…

3D silicon detectors, in which the electrodes penetrate the sensor bulk perpendicular to the surface, have recently undergone a rapid development from R\&D over industrialisation to their first installation in a real high-energy-physics…

Instrumentation and Detectors · Physics 2015-11-09 Jörn Lange

3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…

The R&D Collaboration SiLC (Silicon tracking for Linear Colliders) is based on generic R&D aiming to develop the next generation of large Silicon tracking systems for the Linear collider experiments; it serves all three ILC detector…

Instrumentation and Detectors · Physics 2009-03-26 Aurore Savoy-Navarro

The International Linear Collider (ILC) is a project of an electron-positron (e+e-) linear collider with the centre-of-mass energy of 200-500 GeV. Monolithic Active Pixel Sensors (MAPS) are one of the proposed silicon pixel detector…

Instrumentation and Detectors · Physics 2010-05-21 Lukasz Maczewski

Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a…

In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their…

High Energy Physics - Experiment · Physics 2019-08-17 M. Caccia , S. Borghi , R. Campagnolo , M. Battaglia , W. Kucewicz , H. Palka , A. Zalewska , K. Domanski , J. Marczewski , D. Tomaszewski

A prototype of the CMOS pixel sensor named SUPIX-1 has been fabricated and tested in order to investigate the feasibility of a pixelated tracker for a proposed Higgs factory, namely, the Circular Electron-Positron Collider (CEPC). The…

Instrumentation and Detectors · Physics 2022-01-05 L. Li , L. Zhang , J. N. Dong , J. Liu , M. Wang

This report reviews current trends in the R&D of semiconductor pixellated sensors for vertex tracking and radiation imaging. It identifies requirements of future HEP experiments at colliders, needed technological breakthroughs and…

Thin planar silicon sensors with a pitch of 55um, active edge and various guard ring layouts are investigated, using two-dimensional finite-element T-CAD simulations. The simulation results have been compared to experimental data, and an…

The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…

Accelerator Physics · Physics 2008-11-26 Jean-Pierre Delahaye , Ian Wilson

Over the past few years we have developed, in collaboration with the SARNOFF Corporation, a design of a Monolithic CMOS Pixel Detector for ILC Vertex Detectors. The unique feature of this design is that each hit is accompanied by a time tag…

Instrumentation and Detectors · Physics 2011-09-14 C. Baltay , W. Emmet , D. Rabinowitz , J. Brau , N. Sinev , D. Strom

The concept of capacitive coupling between sensors and readout chips is under study for the vertex detector at the proposed high-energy CLIC electron positron collider. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is an active…

Instrumentation and Detectors · Physics 2017-10-06 I. Kremastiotis , R. Ballabriga , M. Campbell , D. Dannheim , A. Fiergolski , D. Hynds , S. Kulis , I. Peric

The CMS tracker consists of two tracking systems utilizing semiconductor technology: the inner pixel and the outer strip detectors. The tracker detectors occupy the volume around the beam interaction region between 3 cm and 110 cm in radius…

Instrumentation and Detectors · Physics 2018-01-10 Viktor Veszpremi

CMOS Pixel Sensors are making steady progress towards the specifications of the ILD vertex detector. Recent developments are summarised, which show that these devices are close to comply with all major requirements, in particular the…

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…

Instrumentation and Detectors · Physics 2025-10-16 The Tracker Group of the CMS Collaboration

The High Luminosity upgrade of the CERN Large Hadron Collider will be able to reach a peak instantaneous luminosity of 5E34/cm2 s. The innermost detectors of the CMS and ATLAS experiments will have to cope with unprecedented requirements on…

Instrumentation and Detectors · Physics 2021-06-16 Jordi Duarte-Campderros