Related papers: Security-Constrained Multi-Objective Optimal Power…
In order to unifiedly coordinate economy and voltage deviations, a novel multi-objective optimal power flow (MOPF) algorithm is proposed for an AC/DC system with VSC-HVDC based on cooperative multi-objective particle swarm optimization…
A two-stage solution approach for solving the problem of multi-objective optimal power flow (MOPF) is proposed for hybrid AC/DC grids with VSC-HVDC. First, a MOPF model for hybrid AC/DC grids is built to coordinate the economy, voltage…
A fast and scalable iterative methodology for solving the security-constrained optimal power flow (SCOPF) problem is proposed using problem decomposition and the inverse matrix modification lemma. The SCOPF formulation tackles system…
In this paper, we discuss our approach and algorithmic framework for solving large-scale security constrained optimal power flow (SCOPF) problems. SCOPF is a mixed integer non-convex optimization problem that aims to obtain the minimum…
The accelerated penetration rate of renewable energy sources (RES) brings environmental benefits at the expense of increasing operation cost and undermining the satisfaction of the N-1 security criterion. To address the latter issue, this…
This paper presents a security-constrained optimal power flow (SCOPF) model for HVDC grids that optimizes the asymmetrical operation of bipolar converter stations, i.e., different current injections of the positive and negative converter…
In this paper, we study efficient and robust computational methods for solving the security-constrained alternating current optimal power flow (SC-ACOPF) problem, a two-stage nonlinear optimization problem with disjunctive constraints, that…
With the growing integration of modular multilevel converters (MMCs) in Multi-Terminal Direct Current (MTDC) transmission systems, there is an increasing need for control strategies that ensure both economic efficiency and robust dynamic…
AC/multi-terminal DC (MTDC) hybrid power systems have emerged as a solution for the large-scale and longdistance accommodation of power produced by renewable energy systems (RESs). To ensure the optimal operation of such hybrid power…
Security-constrained unit commitment with alternating current optimal power flow (SCUC-ACOPF) is a central problem in power grid operations that optimizes commitment and dispatch of generators under a physically accurate power transmission…
For the purpose of addressing the multi-objective optimal reactive power dispatch (MORPD) problem, a two-step approach is proposed in this paper. First of all, to ensure the economy and security of the power system, the MORPD model aiming…
With the increasing complexity of power systems, faster methods for power system reliability analysis are needed. We propose a novel methodology to solve the security constrained optimal power flow (SCOPF) problem that reduces the…
To figure out the stability issues brought by renewable energy sources (RES) with non-Gaussian uncertainties in isolated microgrids, this paper proposes a chance constrained stability constrained optimal power flow (CC-SC-OPF) model.…
To coordinate the economy, security and environment protection in the power system operation, a two-step many-objective optimal power flow (MaOPF) solution method is proposed. In step 1, it is the first time that knee point-driven…
In this paper, we present an optimization algorithm based on an alternating projection method to solve the large-scale security constraint optimal power flow (SCOPF) problem in power systems. The SCOPF is first partitioned into…
The uncertainty of multiple power loads and renewable energy generations (PLREG) in power systems increases the complexity of power flow analysis for decision-makers. The chance-constrained method can be applied to model the optimization…
Optimizing operational set points for modular multilevel converters (MMCs) in Multi-Terminal Direct Current (MTDC) transmission systems is crucial for ensuring efficient power distribution and control. This paper presents an enhanced…
The chance constrained optimal power flow (CC-OPF) essentially finds the low-cost generation dispatch scheme ensuring operational constraints are met with a specified probability, termed the security level. While the security level is a…
Determining contingency aware dispatch decisions by solving a security-constrained optimal power flow (SCOPF) is challenging for real-world power systems, as the high problem dimensionality often leads to impractical computational…
Stepwise controllable devices, such as switched capacitors or stepwise controllable loads and generators, transform the nonconvex AC optimal power flow (AC-OPF) problem into a nonconvex mixed-integer (MI) programming problem which is…