English
Related papers

Related papers: Deep autofocus with cone-beam CT consistency const…

200 papers

Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Alexander Preuhs , Michael Manhart , Philipp Roser , Bernhard Stimpel , Christopher Syben , Marios Psychogios , Markus Kowarschik , Andreas Maier

Metal artifacts in computed tomography (CT) arise from a mismatch between physics of image formation and idealized assumptions during tomographic reconstruction. These artifacts are particularly strong around metal implants, inhibiting…

Image and Video Processing · Electrical Eng. & Systems 2019-09-20 Jan-Nico Zaech , Cong Gao , Bastian Bier , Russell Taylor , Andreas Maier , Nassir Navab , Mathias Unberath

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

Computer Vision and Pattern Recognition · Computer Science 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or…

Computer Vision and Pattern Recognition · Computer Science 2024-03-28 Mohammadreza Amirian , Daniel Barco , Ivo Herzig , Frank-Peter Schilling

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides…

Computer Vision and Pattern Recognition · Computer Science 2022-01-20 Mareike Thies , Jan-Nico Zäch , Cong Gao , Russell Taylor , Nassir Navab , Andreas Maier , Mathias Unberath

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

Computer Vision and Pattern Recognition · Computer Science 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

Image and Video Processing · Electrical Eng. & Systems 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…

Computer Vision and Pattern Recognition · Computer Science 2018-12-11 Haofu Liao , Zhimin Huo , William J. Sehnert , Shaohua Kevin Zhou , Jiebo Luo

Conebeam CT using a circular trajectory is quite often used for various applications due to its relative simple geometry. For conebeam geometry, Feldkamp, Davis and Kress algorithm is regarded as the standard reconstruction method, but this…

Image and Video Processing · Electrical Eng. & Systems 2020-06-04 Yoseob Han , Junyoung Kim , Jong Chul Ye

Cone-beam computed tomography (CBCT) is an important tool facilitating computer aided interventions, despite often suffering from artifacts that pose challenges for accurate interpretation. While the degraded image quality can affect…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

Metal artifacts present a frequent challenge to cone-beam CT (CBCT) in image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy. Recent advances in mobile C-arm systems have enabled 3D imaging capacity with…

Cone-beam computed tomography (CBCT) is a widely used 3D imaging technique in dentistry, offering high-resolution images while minimising radiation exposure for patients. However, CBCT is highly susceptible to artefacts arising from…

Computer Vision and Pattern Recognition · Computer Science 2026-03-09 Susanne Schaub , Florentin Bieder , Matheus L. Oliveira , Yulan Wang , Dorothea Dagassan-Berndt , Michael M. Bornstein , Philippe C. Cattin

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

Image and Video Processing · Electrical Eng. & Systems 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

Medical Physics · Physics 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

Medical Physics · Physics 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

Medical Physics · Physics 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

Interventional C-arm systems allow flexible 2-D imaging of a 3-D scene while being capable of cone beam computed tomography. Due to the flexible structure of the C-arm, the rotation speed is limited, increasing the acquisition time compared…

Medical Physics · Physics 2018-07-25 Alexander Preuhs , Michael Manhart , Andreas Maier

This study introduces a novel reconstruction method for dental cone-beam computed tomography (CBCT), focusing on effectively reducing metal-induced artifacts commonly encountered in the presence of prevalent metallic implants. Despite…

Computer Vision and Pattern Recognition · Computer Science 2023-07-28 Hyoung Suk Park , Kiwan Jeon , Jin Keun Seo
‹ Prev 1 2 3 10 Next ›