Related papers: Data processing over single-port homodyne detectio…
Accurate phase estimation in the presence of unknown phase diffusive noise is a crucial yet challenging task in noisy quantum metrology. This problem is particularly interesting due to the detrimental impact of the associated noise. Here,…
We suggest an interferometric scheme assisted by squeezing and linear feedback to realize the whole class of field-quadrature quantum nondemolition measurements, from Von Neumann projective measurement to fully non-destructive…
In this letter, we propose a quantum integrated sensing and communication scheme for a quantum optical link using binary phase-shift keying modulation and homodyne detection. The link operates over a phase-insensitive Gaussian channel with…
A recently proposed phase-estimation protocol that is based on measuring the parity of a two-mode squeezed-vacuum state at the output of a Mach-Zehnder interferometer shows that Cram\'{e}r-Rao bound sensitivity can be obtained [P.\ M.\…
We study a model of a two-level system (i.e. a qubit) in interaction with the electromagnetic field. By means of homodyne detection, one field-quadrature is observed continuously in time. Due to the interaction, information about the…
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, 'truncated SU(1,1)' interferometer Anderson et al. (Phys. Rev. A 95, 063843 (2017)) showed how to optimize the…
We report on amplitude and phase imaging of out-of-plane sinusoidal surface vibration at nanometer scales with a heterodyne holographic interferometer. The originality of the proposed method is to make use of a multiplexed local oscillator…
To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…
Particle sensing in optical tweezers systems provides information on the position, velocity and force of the specimen particles. The conventional quadrant detection scheme is applied ubiquitously in optical tweezers experiments to quantify…
We consider the phase sensing via weak optical coherent state at quantum limit precision. A new detection scheme for the phase estimation is proposed which is inspired by the suboptimal quantum measurement in coherent optical communication.…
Phase super-sensitivity is obtained when the sensitivity in a phase measurement goes beyond the quantum shot noise limit, whereas super-resolution is obtained when the interference fringes in an interferometer are narrower than half the…
While quantum metrology enables measurement precision beyond classical limits, its performance is often susceptible to experimental imperfections. Most prior studies have focused on imperfections in quantum states and operations. Here, we…
Future interferometric gravitational wave detectors will make use of the coupling between shot noise and radiation pressure noise that produces a squeezed output for the quantum noise at the dark-port of the interferometer allowing these…
Phase diffusion represents a crucial obstacle towards the implementation of high precision interferometric measurements and phase shift based communication channels. Here we present a nearly optimal interferometric scheme based on homodyne…
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input…
We present a fully Gaussian and experimentally feasible scheme for the simultaneous estimation of the four real parameters that characterize an arbitrary two-channel unitary transformation. The scheme utilizes a two-mode squeezed probe and…
Estimation of the properties of a physical system with minimal uncertainty is a central task in quantum metrology. Optical phase estimation is at the center of many metrological tasks where the value of a physical parameter is mapped to the…
It is shown that the maximal phase sensitivity of a two-path interferometer with high-intensity coherent light and squeezed vacuum in the input ports can be achieved by photon-number-resolving detection of only a small number of photons in…
A general one-dimensional quantum optical mode is described by a shape in the time or frequency domain. A fundamental problem is to measure a quadrature operator of such a mode. If the shape is narrow in frequency this can be done by pulsed…
A two-step detection strategy is suggested for the precise measurement of the optical phase-shift. In the first step an unsharp, however, unbiased joint measurement of the phase and photon number is performed by heterodyning the signal…