Related papers: Improving FLAIR SAR efficiency at 7T by adaptive t…
Purpose: To develop a method for rapid sub-millimeter T1, T2, T2* and QSM mapping in a single scan using multi-contrast Learned Acquisition and Reconstruction Optimization (mcLARO). Methods: A pulse sequence was developed by interleaving…
Purpose: Rapid 2D RF pulse design with subject specific $B_1^+$ inhomogeneity and $B_0$ off-resonance compensation at 7 T predicted from convolutional neural networks is presented. Methods: The convolution neural network was trained on half…
Recent studies on T1-assisted MRI reconstruction for under-sampled images of other modalities have demonstrated the potential of further accelerating MRI acquisition of other modalities. Most of the state-of-the-art approaches have achieved…
Purpose: To develop schemes that deliver faithful 2D slices near field heterogeneities of the kind arising from non-ferromagnetic metal implants, with reduced artifacts and shorter scan times. Methods: An excitation scheme relying on…
Purpose: Designing a new T2 preparation (T2-Prep) module in order to simultaneously provide robust fat suppression and efficient T2 preparation without requiring an additional fat suppression module for T2-weighted imaging at 3T. Methods:…
Purpose: To address the systematic bias in whole-brain dual flip angle (DFA) T1-mapping at 7T by optimizing the flip angle pair and carefully selecting RF pulse shape and duration. Theory and Methods: Spoiled gradient echoes can be used to…
Adiabatic Bloch-Siegert B1+ mapping method addresses the long TE and high RF power deposition problems of conventional Bloch-Siegert B1+ mapping by introducing short frequency-swept ABS pulses with maximum sensitivity. Here, it is shown how…
With the development of the upcoming sixth-generation (6G) wireless networks, there is a pressing need for innovative technologies capable of satisfying heightened performance indicators. Fluid antenna system (FAS) is proposed recently as a…
Purpose: Magnetic resonance imaging (MRI) exams include multiple series with varying contrast and redundant information. For instance, T2-FLAIR contrast is based upon tissue T2 decay and the presence of water, also present in T2- and…
Cardiac T1 mapping provides critical quantitative insights into myocardial tissue composition, enabling the assessment of pathologies such as fibrosis, inflammation, and edema. However, the inherently dynamic nature of the heart imposes…
Adiabatic mode evolution waveguides (AMEWs) are widely utilized in integrated photonics, including tapered waveguides, edge couplers, mode converters, splitters, etc. An analytical theory and a novel AMEW design algorithm are developed to…
T2 weighted imaging of the spine is commonly performed using fast spin echo (FSE/TSE) based sequences, resulting in long scan times and vulnerability to motion artifacts. While single shot fast spin echo sequences have been attempted, their…
Purpose: To develop a free-breathing myocardial T1 mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction. Methods: Free-running (free-breathing,…
Purpose: To non-heuristically identify dedicated variable flip angle (VFA) schemes optimized for the point-spread function (PSF) and signal-to-noise ratio (SNR) of multiple tissues in 3D FSE sequences with very long echo trains at 7T.…
Balanced steady-state free precession (bSSFP) imaging enables high scan efficiency in MRI, but differs from conventional sequences in terms of elevated sensitivity to main field inhomogeneity and nonstandard T2/T1-weighted tissue contrast.…
Synthetic aperture radar (SAR) imaging plays a critical role in all-weather, day-and-night remote sensing, yet reconstruction is often challenged by noise, undersampling, and complex scattering scenarios. Conventional methods, including…
Dispersion management of few-cycle pulses is crucial for ultrafast optics and photonics. Often, nontrivial dispersion is compensated using complex optical systems or minimized through careful design of waveguides. Here, we present…
Purpose: To develop a cardiac T1 mapping method for free-breathing 3D T1 mapping of the whole heart at 3T with transmit B1 (B1+) correction Methods: A free-breathing, ECG-gated inversion recovery sequence with spoiled gradient-echo readout…
Diffusion-weighted magnetic resonance imaging (DW-MRI) is a powerful, non-invasive tool for detecting and characterizing abdominal lesions to facilitate early diagnosis, but respiratory motion during a scan reduces image quality and…
This work is to develop a general framework, namely analytical iterative reconstruction (AIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality and…