This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

Computational Engineering, Finance, and Science · Computer Science 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

Magnetic Resonance (MR) Imaging and Computed Tomography (CT) are the primary diagnostic imaging modalities quite frequently used for surgical planning and analysis. A general problem with medical imaging is that the acquisition process is…

Image and Video Processing · Electrical Eng. & Systems 2020-06-08 Vismay Agrawal , Avinash Kori , Vikas Kumar Anand , Ganapathy Krishnamurthi

Metal artifacts from high-attenuation implants severely degrade CT image quality, obscuring critical anatomical structures and posing a challenge for standard deep learning methods that require extensive paired training data. We propose a…

Computer Vision and Pattern Recognition · Computer Science 2026-04-08 Ahmet Rasim Emirdagi , Süleyman Aslan , Mısra Yavuz , Görkay Aydemir , Yunus Bilge Kurt , Nasrin Rahimi , Burak Can Biner , M. Akın Yılmaz

To facilitate a prospective estimation of CT effective dose and risk minimization process, a prospective spatial dose estimation and the known anatomical structures are expected. To this end, a CT reconstruction method is required to…

Image and Video Processing · Electrical Eng. & Systems 2024-01-24 Chang Liu , Laura Klein , Yixing Huang , Edith Baader , Michael Lell , Marc Kachelrieß , Andreas Maier

Cone Beam Computed Tomography (CBCT) plays a key role in dental diagnosis and surgery. However, the metal teeth implants could bring annoying metal artifacts during the CBCT imaging process, interfering diagnosis and downstream processing…

Image and Video Processing · Electrical Eng. & Systems 2024-04-19 Yuxuan Shi , Jun Xu , Dinggang Shen

With the advent of Deep Learning (DL) techniques, especially Generative Adversarial Networks (GANs), data augmentation and generation are quickly evolving domains that have raised much interest recently. However, the DL techniques are data…

Computer Vision and Pattern Recognition · Computer Science 2018-05-30 Umair Javaid , John A. Lee

For the task of metal artifact reduction (MAR), although deep learning (DL)-based methods have achieved promising performances, most of them suffer from two problems: 1) the CT imaging geometry constraint is not fully embedded into the…

Image and Video Processing · Electrical Eng. & Systems 2021-09-14 Hong Wang , Yuexiang Li , Haimiao Zhang , Jiawei Chen , Kai Ma , Deyu Meng , Yefeng Zheng

Computed tomography (CT) can provide a 3D view of the patient's internal organs, facilitating disease diagnosis, but it incurs more radiation dose to a patient and a CT scanner is much more cost prohibitive than an X-ray machine too.…

Image and Video Processing · Electrical Eng. & Systems 2019-05-17 Xingde Ying , Heng Guo , Kai Ma , Jian Wu , Zhengxin Weng , Yefeng Zheng

The shortage of annotated medical images is one of the biggest challenges in the field of medical image computing. Without a sufficient number of training samples, deep learning based models are very likely to suffer from over-fitting…

Image and Video Processing · Electrical Eng. & Systems 2021-01-14 Xiaocong Chen , Yun Li , Lina Yao , Ehsan Adeli , Yu Zhang

Computed tomography (CT) is critical for various clinical applications, e.g., radiotherapy treatment planning and also PET attenuation correction. However, CT exposes radiation during acquisition, which may cause side effects to patients.…

Computer Vision and Pattern Recognition · Computer Science 2016-12-19 Dong Nie , Roger Trullo , Caroline Petitjean , Su Ruan , Dinggang Shen

Metal implants and other high-density objects in patients introduce severe streaking artifacts in CT images, compromising image quality and diagnostic performance. Although various methods were developed for CT metal artifact reduction over…

Image and Video Processing · Electrical Eng. & Systems 2024-01-10 Zilong Li , Qi Gao , Yaping Wu , Chuang Niu , Junping Zhang , Meiyun Wang , Ge Wang , Hongming Shan

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

Image and Video Processing · Electrical Eng. & Systems 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

Standard methods for generating adversarial examples for neural networks do not consistently fool neural network classifiers in the physical world due to a combination of viewpoint shifts, camera noise, and other natural transformations,…

Computer Vision and Pattern Recognition · Computer Science 2018-06-08 Anish Athalye , Logan Engstrom , Andrew Ilyas , Kevin Kwok

In this paper, we present a novel adversarial lossy video compression model. At extremely low bit-rates, standard video coding schemes suffer from unpleasant reconstruction artifacts such as blocking, ringing etc. Existing learned neural…

Image and Video Processing · Electrical Eng. & Systems 2021-06-22 Vijay Veerabadran , Reza Pourreza , Amirhossein Habibian , Taco Cohen

Deep learning has a great potential to alleviate diagnosis and prognosis for various clinical procedures. However, the lack of a sufficient number of medical images is the most common obstacle in conducting image-based analysis using deep…

Image and Video Processing · Electrical Eng. & Systems 2022-05-23 Marija Habijan , Irena Galic

Metal artifacts, caused by high-density metallic implants in computed tomography (CT) imaging, severely degrade image quality, complicating diagnosis and treatment planning. While existing deep learning algorithms have achieved notable…

Computer Vision and Pattern Recognition · Computer Science 2025-08-15 Farid Tasharofi , Fuxin Fan , Melika Qahqaie , Mareike Thies , Andreas Maier

High density implants such as metals often lead to serious artifacts in the reconstructed CT images which hampers the accuracy of image based diagnosis and treatment planning. In this paper, we propose a novel wavelet frame based CT image…

Medical Physics · Physics 2017-11-21 Haimiao Zhang , Bin Dong , Baodong Liu

Dense depth estimation and 3D reconstruction of a surgical scene are crucial steps in computer assisted surgery. Recent work has shown that depth estimation from a stereo images pair could be solved with convolutional neural networks.…

Image and Video Processing · Electrical Eng. & Systems 2021-07-24 Baoru Huang , Jianqing Zheng , Anh Nguyen , David Tuch , Kunal Vyas , Stamatia Giannarou , Daniel S. Elson

In recent years, many convolutional neural network-based models are designed for JPEG artifacts reduction, and have achieved notable progress. However, few methods are suitable for extreme low-bitrate image compression artifacts reduction.…

Computer Vision and Pattern Recognition · Computer Science 2023-05-05 Xuhao Jiang , Weimin Tan , Qing Lin , Chenxi Ma , Bo Yan , Liquan Shen

Image translation across domains for unpaired datasets has gained interest and great improvement lately. In medical imaging, there are multiple imaging modalities, with very different characteristics. Our goal is to use cross-modality…

Image and Video Processing · Electrical Eng. & Systems 2022-02-07 Leo Segre , Or Hirschorn , Dvir Ginzburg , Dan Raviv