English
Related papers

Related papers: Surface background rejection technique for liquid …

200 papers

Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a…

Instrumentation and Detectors · Physics 2021-08-11 L. Wang , M. Y. Guan , H. J. Qin , C. Guo , X. L. Sun , C. G. Yang , Q. Zhao , J. C. Liu , P. Zhang , Y. P. Zhang , W. X. Xiong , Y. T. Wei , Y. Y. Gan , J. J. Li

Neutrons are a particularly dangerous background for direct WIMP dark matter searches; their nuclear recoils with the target nucleus are often indistinguishable from nuclear recoils produced by WIMP-nuclear collisions. In this study, we…

Instrumentation and Detectors · Physics 2016-04-06 Shawn Westerdale , Emily Shields , Frank Calaprice

We consider the prospects for the detection of relatively light dark matter through direct annihilation to neutrinos. We specifically focus on the detection possibilities of water Cherenkov and liquid scintillator neutrino detection…

High Energy Physics - Phenomenology · Physics 2010-04-30 Jason Kumar , John G. Learned , Stefanie Smith

Liquid argon is an excellent medium for detecting particles, given its yields and transport properties of light and charge. The technology of liquid argon time projection chambers has reached its full maturity after four decades of…

High Energy Physics - Experiment · Physics 2024-05-03 Ettore Segreto

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches,…

Instrumentation and Detectors · Physics 2017-11-22 The DarkSide Collaboration , P. Agnes , I. F. M. Albuquerque , T. Alexander , A. K. Alton , D. M. Asner , H. O. Back , K. Biery , V. Bocci , G. Bonfini , W. Bonivento , M. Bossa , B. Bottino , F. Budano , S. Bussino , M. Cadeddu , M. Cadoni , F. Calaprice , N. Canci , A. Candela , M. Caravati , M. Cariello , M. Carlini , S. Catalanotti , V. Cataudella , P. Cavalcante , A. Chepurnov , C. Cicalo , A. G. Cocco , G. Covone , D. D'Angelo , M. D'Incecco , S. Davini , A. de Candia , S. De Cecco , M. De Deo , G. De Filippis , M. De Vincenzi , A. V. Derbin , G. De Rosa , A. Devoto , F. Di Eusanio , G. Di Pietro , C. Dionisi , E. Edkins , A. Empl , A. Fan , G. Fiorillo , K. Fomenko , D. Franco , F. Gabriele , C. Galbiati , S. Giagu , C. Giganti , G. K. Giovanetti , A. M. Goretti , F. Granato , M. Gromov , M. Guan , Y. Guardincerri , B. R. Hackett , K. Herner , D. Hughes , P. Humble , E. V. Hungerford , An. Ianni , I. James , T. N. Johnson , K. Keeter , C. L. Kendziora , G. Koh , D. Korablev , G. Korga , A. Kubankin , X. Li , M. Lissia , B. Loer , G. Longo , Y. Ma , A. A. Machado , I. N. Machulin , A. Mandarano , S. M. Mari , J. Maricic , C. J. Martoff , P. D. Meyers , R. Milincic , A. Monte , B. J. Mount , V. N. Muratova , P. Musico , J. Napolitano , A. Navrer Agasson , A. Oleinik , M. Orsini , F. Ortica , L. Pagani , M. Pallavicini , E. Pantic , K. Pelczar , N. Pelliccia , A. Pocar , S. Pordes , D. A. Pugachev , H. Qian , K. Randle , M. Razeti , A. Razeto , B. Reinhold , A. L. Renshaw , M. Rescigno , Q. Riffard , A. Romani , B. Rossi , N. Rossi , D. Sablone , W. Sands , S. Sanfilippo , C. Savarese , B. Schlitzer , E. Segreto , D. A. Semenov , P. N. Singh , M. D. Skorokhvatov , O. Smirnov , A. Sotnikov , C. Stanford , Y. Suvorov , R. Tartaglia , G. Testera , A. Tonazzo , P. Trinchese , E. V. Unzhakov , M. Verducci , A. Vishneva , B. Vogelaar , M. Wada , S. Walker , H. Wang , Y. Wang , A. W. Watson , S. Westerdale , J. Wilhelmi , M. M. Wojcik , X. Xiang , X. Xiao , C. Yang , Z. Ye , C. Zhu , G. Zuzel

The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector…

This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics and medical imaging experiments. We begin with a summary of the fundamental…

Instrumentation and Detectors · Physics 2010-12-01 E. Aprile , T. Doke

Liquid argon (LAr) with a high light yield of approximately 40 photons per keV is an attractive target for the direct detection of weakly interacting massive particles (WIMPs), which are well motivated galactic dark matter candidates. We…

Instrumentation and Detectors · Physics 2018-06-26 X. Zhu , Z. Shen , C. Feng , S. Liu , Q. An

We investigate novel strategies to extend the sensitivity of dark matter direct detection experiments to energy deposits well below the thresholds of conventional detectors. In liquid-argon time-projection chambers equipped with silicon…

Instrumentation and Detectors · Physics 2026-01-12 Faeq Abed , Asmaa AlMellah , Kareem Al-Jubouri , Alex Lumoski

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6x6x6 m$^3$ liquid argon…

Instrumentation and Detectors · Physics 2022-01-19 I. Gil-Botella

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the…

Instrumentation and Detectors · Physics 2015-09-02 W. Creus , Y. Allkofer , C. Amsler , A. D. Ferella , J. Rochet , L. Scotto-Lavina , M. Walter

WIMPs are a well-motivated galactic dark matter candidate. Liquid argon (LAr) is an attractive target for the direct detection of WIMPs. The LAr prototype detector is designed to study the technology and property of LAr detector. The…

Instrumentation and Detectors · Physics 2016-12-21 Pei-Xian Li , Meng-Yun Guan , Chang-Gen Yang , Peng Zhang , Jin-Chang Liu , Yong-Pen Zhang , Cong Guo , Yi Wang

An ultimate liquid xenon experiment would be limited in its dark matter science reach by irreducible neutrino backgrounds, which are an exciting signal in their own right. To achieve such sensitivity, other backgrounds that currently plague…

High Energy Physics - Experiment · Physics 2024-02-27 Abigail Kopec

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the…

Instrumentation and Methods for Astrophysics · Physics 2018-06-13 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , B. Antunes , F. Arneodo , M. Balata , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , A. Breskin , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , A. Chiarini , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , R. Corrieri , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , J. -M. Disdier , M. Doets , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Florin , D. Front , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , K. -L. Giboni , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , C. Huhmann , R. Itay , A. James , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , R. Maier , A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , D. Orlandi , R. Othegraven , P. Pakarha , S. Parlati , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , V. Pizzella , M. -C. Piro , G. Plante , N. Priel , D. Ramírez García , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , J. M. F. dos Santos , R. Saldahna , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , M. Stern , A. Stein , D. Tatananni , L. Tatananni , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , M. Vargas , O. Wack , R. Walet , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , C. Wittweg , J. Wulf , J. Ye , Y. Zhang

The Deep Underground Neutrino Experiment (DUNE) Far Detector (FD) will be formed by four 10-kton Liquid Argon (LAr) Time Projection Chambers (TPC) using both single and dual-phase technology. The dual-phase technology foreseen the charge…

Instrumentation and Detectors · Physics 2019-11-19 Chiara Lastoria

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a…

Instrumentation and Detectors · Physics 2018-04-18 G. Cancelo , F. Cavanna , C. O. Escobar , E. Kemp , A. A. Machado , A. Para , E. Segreto , D. Totani , D. Warner

DARWIN (dark matter wimp search with noble liquids) is a design study for a next-generation, multi-ton dark matter detector in Europe. Liquid argon and/or liquid xenon are the target media for the direct detection of dark matter candidates…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Laura Baudis

A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd…

Instrumentation and Detectors · Physics 2015-11-25 T. Heindl , T. Dandl , M. Hofmann , R. Krücken , L. Oberauer , W. Potzel , J. Wieser , A. Ulrich

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

Instrumentation and Detectors · Physics 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups

DEAP-3600 is the largest running dark matter detector filled with liquid argon, set at SNOLAB, in Sudbury, Canada, 2 km underground. The experiment holds the most stringent exclusion limit in argon for WIMPs above 20 GeV/c$^2$. In the most…

High Energy Physics - Experiment · Physics 2023-03-01 Michela Lai
‹ Prev 1 4 5 6 7 8 10 Next ›