Abnormal event detection is critical in the safe operation of power system. In this paper, using the data collected from phasor measurement units (PMUs), two methods based on Fisher random matrix are proposed to detect faults in power…
Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro…
This paper focuses on a networked state estimation problem for a spatially large linear system with a distributed array of sensors, each of which offers partial state measurements, and the transmission is lossy. We propose a measurement…
In design of new power transformers, reliable and efficient tools are required to expedite research and development processes. Some of these tools are used to interpret the data obtained from the transformer tests for better judgement about…
Assuming access to synchronized stream of Phasor Measurement Unit (PMU) data over a significant portion of a power system interconnect, say controlled by an Independent System Operator (ISO), what can you extract about past, current and…
In this paper we study the question of how to reconstruct the state of a power system using Phasor Measurement Units (PMUs). In our previous research we proved that this question has an affirmative answer imposing some rather strict…
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by…
The prompt and accurate detection of faults and abnormalities in electric transmission lines is a critical challenge in smart grid systems. Existing methods mostly rely on model-based approaches, which may not capture all the aspects of…
Compressed sensing typically deals with the estimation of a system input from its noise-corrupted linear measurements, where the number of measurements is smaller than the number of input components. The performance of the estimation…
A new feature selection method based on an improved maximal relevance and minimal redundancy (mRMR) criterion was proposed for power system transient stability assessment. First, the standard mRMR was improved by introducing a weight…
In modern power systems, grid-forming power converters (GFMCs) have emerged as an enabling technology. However, the modeling of single-phase GFMCs faces new challenges. In particular, the nonlinear orthogonal signal generation unit, crucial…
In a typical multi-standard military communication receiver, fast and reliable spectrum sensing unit is required to extract the information of multiple channels (frequency bands) present in a wideband input signal. In this paper, an energy…
Despite wide-scale deployment of phasor measurement unit technology, locating the sources of low frequency forced oscillations in power systems is still an open research topic. The dissipating energy flow method is one source location…
In this paper, least square estimation (LSE)-based dynamic generator model parameter identification is investigated. Electromechanical dynamics related parameters such as inertia constant and primary frequency control droop for a…
This paper proposes a source-independent method for the detection and classification of faults along Transmission Lines (TLs). It aims to reduce the protection issues arising from Inverter-Based Resources (IBRs). Inspired by Power Line…
All 21-cm signal experiments rely on electronic receivers that affect the data via both multiplicative and additive biases through the receiver's gain and noise temperature. While experiments attempt to remove these biases, the residuals of…
Reducing the current is a common method to ensure the synchronous stability of a modular multilevel converter (MMC) when there is a short-circuit fault at its AC side. However, the uncertainty of the fault location of the AC system leads to…
In quantum multiparameter estimation, multiple to-be-estimated parameters are encoded in a quantum dynamics system by a unitary evolution. As the parameters vary, the system may undergo a topological phase transition (TPT). In this paper,…
This paper proposes a data-driven approach to detect the switching actions and topology transitions in distribution networks. It is based on the real time analysis of time-series voltages measurements. The analysis approach draws on data…
This paper proposes a new approach to perform small-signal stability analysis based on linearization of implicit multilinear models. Multilinear models describe the system dynamics by multilinear functions of state, input, and algebraic…