Related papers: High-Resolution, Respiratory-Resolved Coronary MRA…
Robust and homogeneous lipid suppression is mandatory for coronary magnetic resonance angiography (MRA) since coronary arteries are commonly embedded in fat. However, effective large volume lipid suppression becomes challenging when…
Purpose: To develop a MRI acquisition and reconstruction framework for volumetric cine visualisation of the fetal heart and great vessels in the presence of maternal and fetal motion. Methods: Four-dimensional depiction was achieved using a…
Robotic ultrasound (US) imaging has been seen as a promising solution to overcome the limitations of free-hand US examinations, i.e., inter-operator variability. However, the fact that robotic US systems cannot react to subject movements…
Three-dimensional (3D) ultrasound (US) imaging addresses the limitation in field-of-view (FOV) in conventional two-dimensional (2D) US imaging by providing 3D viewing of the anatomy. 3D US imaging has been extensively adapted for diagnosis…
Deep learning-based 3D imaging, in particular magnetic resonance imaging (MRI), is challenging because of limited availability of 3D training data. Therefore, 2D diffusion models trained on 2D slices are starting to be leveraged for 3D MRI…
To reduce scanning time and/or improve spatial/temporal resolution in some MRI applications, parallel MRI (pMRI) acquisition techniques with multiple coils acquisition have emerged since the early 1990s as powerful 3D imaging methods that…
The perfect alignment of 3D echocardiographic images captured from various angles has improved image quality and broadened the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid…
We propose a fully automated algorithm based on a deep learning framework enabling screening of a coronary computed tomography angiography (CCTA) examination for confident detection of the presence or absence of coronary artery…
Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw…
Background and Purpose: Our purpose was to develop a deep learning angiography (DLA) method to generate 3D cerebral angiograms from a single contrast-enhanced acquisition. Material and Methods: Under an approved IRB protocol 105 3D-DSA…
Cardiac magnetic resonance imaging (MRI) requires reconstructing a real-time video of a beating heart from continuous highly under-sampled measurements. This task is challenging since the object to be reconstructed (the heart) is…
Cardiac magnetic resonance imaging is a valuable non-invasive tool for identifying cardiovascular diseases. For instance, Cine MRI is the benchmark modality for assessing the cardiac function and anatomy. On the other hand, multi-contrast…
A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a…
This paper introduces an innovative methodology for producing high-quality 3D lung CT images guided by textual information. While diffusion-based generative models are increasingly used in medical imaging, current state-of-the-art…
PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a…
Motion correction aims to prevent motion artefacts which may be caused by respiration, heartbeat, or head movements for example. In a preliminary step, the measured data is divided in gates corresponding to motion states, and displacement…
Diffusion-weighted magnetic resonance imaging (DW-MRI) is a powerful, non-invasive tool for detecting and characterizing abdominal lesions to facilitate early diagnosis, but respiratory motion during a scan reduces image quality and…
Motion artifacts often spoil the radiological interpretation of MR images, and in the most severe cases the scan needs be repeated, with additional costs for the provider. We discuss the application of a novel 3D retrospective rigid motion…
Phase-shifting profilometry (PSP) enables high-accuracy 3D reconstruction but remains highly susceptible to object motion. Although numerous studies have explored compensation for motion-induced errors, residual inaccuracies still persist,…
Dynamic three-dimensional (4D) reconstruction from two-dimensional X-ray coronary angiography (CA) remains a significant clinical problem. Existing CA reconstruction methods often require extensive user interaction or large training…