Related papers: Supervised learning of photoelectron counting in s…
Scanning electron microscopy is a powerful tool for nanoscale imaging of organic and inorganic materials. An important metric for characterizing the limits of performance of these microscopes is the Detective Quantum Efficiency (DQE), which…
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…
Photon counting radiation detectors have become an integral part of medical imaging modalities such as Positron Emission Tomography or Computed Tomography. One of the most promising detectors is the wide bandgap room temperature…
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $\pi^+ \to e^+\nu_e(\gamma)$, aka $\pi_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number…
A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are…
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio…
We investigate the kinetic-energy spectrum of electrons emitted from an excited many-electron system, often called photo-electron spectrum (PES). We are particularly interested on the impact of resonant modes of the system on PES. To this…
We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
A new generation of ultra-low-background scintillator-based detectors aims to study solar neutrinos and search for dark matter and new physics beyond the Standard Model. These optical, non-imaging detectors generally contain a "fiducial…
We present the automation of a confocal photoluminescence (PL) scanning system for the identification and characterization of single-photon emitters (SPEs) in quantum materials. The setup excites the sample with a laser and acquires a…
The silicon photo-multipliers (SiPMs) are commonly used in the construction of radiation detectors such as those used in high energy experiments and its applications, where an excellent time resolution is required for triggering. In most of…
The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity…
In recent years, a number of purpose-built scintillator-based polarimeters have studied bright astronomical sources for the first time in the hard X-ray band (tens to hundreds of keV). The addition of polarimetry can help data…
State-of-the-art attosecond metrology deals with the detection and characterization of photon pulses with typical energies up to the hundreds of eV and time resolution of several tens of attoseconds. Such short pulses are used for example…
A 20-kiloton liquid scintillator detector is designed in the Jiangmen Underground Neutrino Observatory (JUNO) for multiple physics purposes, including the determination of the neutrino mass ordering through reactor neutrinos, as well as…
The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light…
Large spherical scintillation detectors are playing an increasingly important role in experimental neutrino physics studies. From the instrumental point of view the primary signal response of these set-ups is constituted by the time and…
Metalenses are optical devices that implement nanostructures as phase shifters to focus incident light. Their compactness and simple fabrication make them a potential cost-effective solution for increasing light collection efficiency in…
Due to their radiation hardness, kilohertz frame rates, and high dynamic range, hybrid pixel detectors have recently expanded their application range to electron diffraction and recently also electron imaging. However, these detectors…