English
Related papers

Related papers: Supervised learning of photoelectron counting in s…

200 papers

This work presents optical calculations and simulations for scintillation detectors used in precision measurements of beta-particle energy spectra. Particular attention is given to Cherenkov photons and the impact of the light detection…

Instrumentation and Detectors · Physics 2025-11-10 S. Vanlangendonck , D. Atanasov , B. Blank , X. Fléchard , M. Kanafani , S. Lecanuet , O. Naviliat-Cuncic , N. Severijns , M. Versteegen

Large-scale detectors consisting of a liquid scintillator target surrounded by an array of photo-multiplier tubes (PMTs) are widely used in the modern neutrino experiments: Borexino, KamLAND, Daya Bay, Double Chooz, RENO, and the upcoming…

Instrumentation and Detectors · Physics 2022-11-15 Arsenii Gavrikov , Yury Malyshkin , Fedor Ratnikov

Photomultiplier tubes (PMTs) are widely deployed at neutrino and dark matter experiments for photon counting. When multiple photons hit a PMT consecutively, their photo-electron (PE) pulses pile up to hinder the precise measurements of the…

High Energy Physics - Experiment · Physics 2025-09-12 Yuyi Wang , Aiqiang Zhang , Yiyang Wu , Benda Xu , Xuewei Liu , Jiajie Chen , Zhe Wang , Shaomin Chen

In low background and low threshold particle astrophysics experiments using observation of Cherenkov or scintillation light it is common to use pairs or arrays of photomultipliers operated in coincidence. In such circumstances, for instance…

Instrumentation and Detectors · Physics 2009-06-23 M. Robinson , P. K. Lightfoot , M. J. Carson , V. A. Kudryavtsev , N. J. C. Spooner

We analyze Photo-Electron Spectra (PES) for a variety of excitation mechanisms from a simple mono-frequency laser pulse to involved combination of pulses as used, e.g., in attosecond experiments. In the case of simple pulses, the peaks in…

Atomic and Molecular Clusters · Physics 2015-05-20 C. -Z. Gao , P. M. Dinh , P. -G. Reinhard , E. Suraud

We discuss in depth the validity and limitations of a theoretical scheme to evaluate photo-electron spectra (PES) through collecting the phase oscillations at a given measuring point. Problems appear if the laser pulse is still active when…

Atomic and Molecular Clusters · Physics 2012-06-19 P. M. Dinh , P. Romaniello , P. -G. Reinhard , E. Suraud

Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…

Instrumentation and Detectors · Physics 2016-03-23 Kareem Kazkaz , Tenzing Henry Yatish Joshi

Photomultiplier tubes (PMTs) are widely employed in particle and nuclear physics experiments. The accuracy of PMT waveform reconstruction directly impacts the detector's spatial and energy resolution. A key challenge arises when multiple…

High Energy Physics - Experiment · Physics 2026-02-06 Kainan Liu , Jingyu Huang , Guihong Huang , Jianyi Luo

The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton…

Instrumentation and Detectors · Physics 2014-03-04 A. Sótér , K. Todoroki , T. Kobayashi , D. Barna , D. Horvath , M. Hori

Imaging the features of a sample using Positron Annihilation Spectroscopy (PAS) is currently achieved by rastering, i.e. by scanning the sample surface with a sharply focused positron beam. However, a beam of arbitrary shape (sculpted beam)…

Instrumentation and Detectors · Physics 2024-02-05 Francesco Guatieri

The KLOE electromagnetic calorimeter is expected to be reused in the Near Detector complex of the DUNE experiment at Fermilab. The possible substitution of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs) in…

Instrumentation and Detectors · Physics 2024-06-19 F. Alemanno , P. Bernardini , A. Corvaglia , G. De Matteis , L. Martina , A. Miccoli , M. Panareo , M. P. Panetta , C. Pinto , A. Surdo

The linear response of a photomultiplier tube (PMT) is a required property for photon counting and reconstruction of the neutrino energy. The linearity valid region and the saturation response of PMT were investigated using a…

Instrumentation and Detectors · Physics 2023-07-12 Hyun-Gi Lee , Jungsic Park

We report on the possibility of using Silicon Photomultipliers (SiPMs) to detect the scintillation light from neutron conversion in ZnS:6LiF scintillators. The light is collected by wavelength-shifting fibers embedded into the scintillator.…

Instrumentation and Detectors · Physics 2015-06-18 A. Stoykov , J. -B. Mosset , U. Greuter , M. Hildebrandt , N. Schlumpf

In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…

Instrumentation and Detectors · Physics 2018-05-23 Mustafa Kandemir , Altan Cakir

A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half…

Instrumentation and Detectors · Physics 2015-05-30 M. Friend , G. B. Franklin , B. Quinn

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

The calorimeter, range detector and active target elements of the T2K near detectors rely on the Hamamatsu Photonics Multi-Pixel Photon Counters (MPPCs) to detect scintillation light produced by charged particles. Detailed measurements of…

Photon readout of plastic scintillators is investigated with the aim of improving the precision of neutron \b{eta} decay experiments. Neutron decay is nowadays studied with high statistics, based on up to 109 registered decay events, and…

Instrumentation and Detectors · Physics 2021-06-08 Dirk Dubbers

The need for purely laboratory-based light pseudoscalar particles searches has been emphasized many times in the literature, since astrophysical bounds on these particles rely on several assumptions to calculate the flux produced in stellar…

High Energy Physics - Phenomenology · Physics 2010-04-23 A. G. Dias , G. Lugones

Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before…

Instrumentation and Detectors · Physics 2009-10-29 N. S. Bowden , P. Marleau , J. T. Steele , S. Mrowka , G. Aigeldinger , W. Mengesha