English
Related papers

Related papers: Improving the Thermal Stability of a CCD Through C…

200 papers

The temperature of the working environment is a key factor in determining the properties of semiconductor detectors, and it affects the absolute accuracy and stability of the standard detector. In order to determine the temperature…

Instrumentation and Detectors · Physics 2016-11-22 Si-Ming Guo , Jin-Jie Wu , Jian Zhang , Xu-Fang Li , Cong-Zhan Liu , Shuai Zhang , Cheng-Ze Li , Bin-Bin Huo , Zhen-Yu Liao

We present a scheme for estimating the noise-equivalent temperature difference (NETD) of frequency upconversion detectors (UCDs) that detect mid-infrared (MIR) light. In particular, this letter investigates the frequency upconversion of a…

The detection of stellar variability often relies on the measurement of selected activity indicators such as coronal emission lines and non-thermal emissions. On the flip side, the effective stellar temperature is normally seen as one of…

A new application of a fast CCD drift scanning technique that allows us to perform speckle imaging of binary stars is presented. For each observation, an arbitrary number of speckle frames is periodically stored on a computer disk, each…

Astrophysics · Physics 2007-05-23 O. Fors , E. P. Horch , J. Nunez

The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $\mu$rad, respectively. Such a precision satisfies the needs of modern crystal…

In this paper we present and analyse determinations of effective temperatures of planet-hosting stars using infrared (IR) photometry. One of our goals is the comparison with spectroscopic temperatures to evaluate the presence of systematic…

Astrophysics · Physics 2009-11-10 I. Ribas , E. Solano , E. Masana , A. Gimenez

Transit spectroscopy of habitable planets orbiting late-type stars requires high relative spectro-photometric accuracy between wavelengths during transit/eclipse observation. The spectro-photometric signal is not affected only by image…

Earth and Planetary Astrophysics · Physics 2018-12-05 Shohei Goda , Taro Matsuo

New generation Cadmium Telluride (CZT & CdTe) solid state detectors can provide high quantum efficiency with reasonably good energy resolution and can operate at near room temperature; an unique advantage for space experiments. We present…

Astrophysics · Physics 2009-11-13 J. S. Yadav , S. Savitri , J. P. Malkar

The detection of planets around very low-mass stars with the radial velocity method is hampered by the fact that these stars are very faint at optical wavelengths where the most high-precision spectrometers operate. We investigate the…

Solar and Stellar Astrophysics · Physics 2014-11-20 A. Reiners , J. L. Bean , K. F. Huber , S. Dreizler , A. Seifahrt , S. Czesla

When Charge Coupled Devices are used for scientific observations, their dark signal is a hindrance. In their pristine state, most CCD pixels are `cool'; they exhibit low, quasi uniform dark current, which can be estimated and corrected for.…

Instrumentation and Methods for Astrophysics · Physics 2015-06-15 J. -F. Hochedez , C. Timmermans , A. Hauchecorne , M. Meftah

The ratio of the depths of spectral lines is a powerful indicator of the effective temperature. The method based on this analysis is capable of discerning small temperature variations of individual stars. We apply this spectroscopic data…

Astrophysics · Physics 2007-05-23 K. Biazzo , A. Frasca , S. Catalano , E. Marilli

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…

We have designed and built a new type of CCD that we call an orthogonal transfer CCD (OTCCD), which permits parallel clocking horizontally as well as vertically. The device has been used successfully to remove image motion caused by…

Astrophysics · Physics 2007-05-23 John L. Tonry , Barry E. Burke , Paul L. Schechter

For atoms or molecules in optical lattices, conventional thermometry methods are often unsuitable due to low particle numbers or a lack of cycling transitions. However, a differential spectroscopic light shift can map temperature onto the…

Atomic Physics · Physics 2015-03-03 Mickey McDonald , Bart H. McGuyer , Geoffrey Z. Iwata , Tanya Zelevinsky

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using…

This work builds on the previous introduction [1] of a coupled experimental-computational system devised to fully characterize the thermal behavior of complex 3D submicron electronic devices. The new system replaces the laser-based surface…

Materials Science · Physics 2007-09-13 Peter E. Raad , Pavel L. Komarov , M. Burzo

To measure low-temperature thermal fields, we have developed a single-element cooled thermal imaging camera for a spectral range of 8{\div}14 {\mu}m with an internal shutter for radiometric calibration. To improve the accuracy of measuring…

Instrumentation and Detectors · Physics 2024-08-30 E. Gordiyenko , Yu. Fomenko , G. Shustakova , G. Kovalov , S. Shevchenko

The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve…

Instrumentation and Detectors · Physics 2016-03-09 S. Murai , A. Ishikawa , T. Sanuki , A. Miyamoto , Y. Sugimoto , C. Constantino , H. Sato , H. Ikeda , Y. Hitoshi

Tearing patterns affecting flat field frames in CCDs are a visually striking obstacle to performing Pixel Response Non-Uniformity corrections. These patterns can be explained by lateral field distortions, caused by the non-uniform…

Instrumentation and Methods for Astrophysics · Physics 2020-02-24 Claire Juramy , Pierre Antilogus , Laurent Le Guillou , Eduardo Sepulveda

Low-cost thermal cameras are inaccurate (usually $\pm 3^\circ C$) and have space-variant nonuniformity across their detector. Both inaccuracy and nonuniformity are dependent on the ambient temperature of the camera. The goal of this work…

Computer Vision and Pattern Recognition · Computer Science 2024-09-10 Navot Oz , Nir Sochen , David Mendelovich , Iftach Klapp
‹ Prev 1 2 3 10 Next ›