English
Related papers

Related papers: Precise calibration method for triaxial magnetomet…

200 papers

This paper describes a novel method for calibrating dc-precise magnetometers in the low field range (100 uT), which gives acceptable results even in laboratory conditions with significant magnetic interference. By introducing a closely…

Instrumentation and Detectors · Physics 2019-09-06 Michal Janosek , Michal Dressler , Vojtech Petrucha , Andrey Chirtsov

Magnetometers, gyroscopes and accelerometers are commonly used sensors in a variety of applications. The paper proposes a novel gyroscope calibration method in the homogeneous magnetic field by the help of magnetometer. It is shown that,…

Robotics · Computer Science 2017-07-25 Yuanxin Wu , Ling Pei

In this paper the techniques available to make and calibrate magnetic search coils are reviewed, with emphasis on harmonic coil systems as the commonly-used optimal choice for integral measurements of accelerator magnets in terms of…

Accelerator Physics · Physics 2011-04-06 M. Buzio

Magnetometer has received wide applications in attitude determination and scientific measurements. Calibration is an important step for any practical magnetometer use. The most popular three-axis magnetometer calibration methods are…

Robotics · Computer Science 2015-09-08 Yuanxin Wu , Wei Shi

A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without…

Accelerator Physics · Physics 2019-03-04 Joseph DiMarco , Giordana Severino , Pasquale Arpaia

This paper developed an efficient method for calibrating triaxial MEMS gyroscopes, which can be effectively utilized in the field environment. The core strategy is to utilize the criterion that the dot product of the measured gravity and…

Robotics · Computer Science 2024-10-28 Yaqi Li , Li Wang , Zhitao Wang , Xiangqing Li , Steven W. Su

We introduce a methodology to calibrate in situ a set of coils generating bi- or tri-axial magnetic fields, at frequencies where a calibration performed under static conditions would be inaccurate. The methodology uses harmonic analysis of…

Instrumentation and Detectors · Physics 2025-07-08 Giuseppe Bevilacqua , Valerio Biancalana , Yordanka Dancheva , Alessandro Fregosi

In this work we present a practical algorithm for calibrating a magnetometer for the presence of magnetic disturbances and for magnetometer sensor errors. To allow for combining the magnetometer measurements with inertial measurements for…

Systems and Control · Computer Science 2016-07-15 Manon Kok , Thomas B. Schön

This paper describes a calibration algorithm to simultaneously calibrate a magnetometer and an accelerometer without any information besides the sensors readings. Using a linear sensor model and maximum likelihood cost, the algorithm is…

Optimization and Control · Mathematics 2015-05-22 Conrado Silva Miranda , Janito Vaqueiro Ferreira

In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs)…

This paper presents an efficient servomotor-aided calibration method for the triaxial gyroscope. The entire calibration process only requires approximately one minute, and does not require high-precision equipment. This method is based on…

Robotics · Computer Science 2021-07-30 Li Wang , Tao Zhang , Lin Ye , Jiao Jiao Li , Steven Su

In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation.…

Atomic Physics · Physics 2025-02-18 Ge Jin , Tao Shi , Sheng Zou

This paper presents an efficient in-field calibration method tailored for low-cost triaxial MEMS gyroscopes often used in healthcare applications. Traditional calibration techniques are challenging to implement in clinical settings due to…

Systems and Control · Electrical Eng. & Systems 2024-08-16 Li Wang , Rob Duffield , Deborah Fox , Athena Hammond , Andrew J. Zhang , Wei Xing Zheng , Steven W. Su

Magnetic surveys are conventionally performed by scanning a domain with a portable scalar magnetic sensor. Unfortunately, scalar magnetometers are expensive, power consuming and bulky. In many applications, calibrated vector magnetometers…

Numerical Analysis · Mathematics 2021-06-29 Roger Alimi , Elad Fisher , Amir Ivry , Alon Shavit , Eyal Weiss

A three-step model for calculating the magnetic field generated by coils inside cuboid-shaped shields like magnetically shielded rooms (MSRs) is presented. The shield is modelled as two parallel plates of infinite width and one tube of…

Applied Physics · Physics 2020-11-17 Tianhao Liu , Allard Schnabel , Jens Voigt , Zhiyin Sun , Liyi Li

The calibration of MEMS triaxial gyroscopes is crucial for achieving precise attitude estimation for various wearable health monitoring applications. However, gyroscope calibration poses greater challenges compared to accelerometers and…

Robotics · Computer Science 2024-06-11 Yaqi Li , Li Wang , Zhitao Wang , Xiangqing Li , Jiaojiao Li , Steven Weidong Su

We present the design and characterization of a ground-based absolute polarization angle calibrator accurate to better than 0.1 degrees for use with polarization sensitive cosmic microwave background (CMB) experiments. The calibrator's…

Instrumentation and Methods for Astrophysics · Physics 2018-09-07 M. F. Navaroli , G. P. Teply , K. D. Crowley , J. P. Kaufman , N. B. Galitzki , K. S. Arnold , B. G. Keating

This is the second of three papers describing an `absolute' calibration of the GONG magnetograph using an end-to-end simulation of its measurement process. In the first paper, we described the GONG instrument and our `end-to-end' simulation…

Solar and Stellar Astrophysics · Physics 2020-11-04 Joseph Plowman , Thomas Berger

The paper proposes a novel calibration approach for the Orthoglide-type mechanisms based on observations of the manipulator leg parallelism during motions between the prespecified test postures. It employs a low-cost measuring system…

Robotics · Computer Science 2007-05-23 Anatoly Pashkevich , Damien Chablat , Philippe Wenger

The paper proposes a novel calibration approach for the Orthoglide-type mechanisms based on observations of the manipulator leg parallelism during mo-tions between the prespecified test postures. It employs a low-cost measuring system…

Robotics · Computer Science 2007-11-13 Anatoly Pashkevich , Damien Chablat , Philippe Wenger
‹ Prev 1 2 3 10 Next ›