English
Related papers

Related papers: How far can we push deconvolution? A SCUBA-2 test …

200 papers

We use the SCUBA-2 submillimeter camera mounted on the JCMT to obtain extremely deep number counts at 450 and 850um. We combine data on two cluster lensing fields, A1689 and A370, and three blank fields, CDF-N, CDF-S, and COSMOS, to measure…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-17 Chian-Chou Chen , Lennox L. Cowie , Amy J. Barger , Caitlin. M. Casey , Nicholas Lee , David B. Sanders , Wei-Hao Wang , Jonathan P. Williams

SCUBA-2 is a 10000-bolometer submillimetre camera on the James Clerk Maxwell Telescope (JCMT). The instrument commissioning was completed in September 2011, and full science operations began in October 2011. To harness the full potential of…

The Submillimetre Common User Bolometer Array 2 (SCUBA-2) is the James Clerk Maxwell Telescope's continuum imager, operating simultaneously at 450 and 850~$\mu$m. SCUBA-2 was commissioned in 2009--2011 and since that time, regular…

Dusty star-forming galaxies (DSFGs) dominate the far-infrared and sub-millimetre number counts, but single-dish surveys suffer from poor angular resolution, complicating mult-wavelength counterpart identification. Prior-driven deblending…

We present an implementation of the iterative flux-conserving Lucy-Richardson (L-R) deconvolution method of image restoration for maps produced by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST). We have analyzed its…

The Submillimetre Common User Bolometer Array 2 (SCUBA-2) is an instrument operating on the 15-m James Clerk Maxwell Telescope, nominally consisting of 5120 bolometers in each of two simultaneous imaging bands centred over 450 and 850 um.…

Instrumentation and Methods for Astrophysics · Physics 2013-03-26 Edward L. Chapin , David S. Berry , Andrew G. Gibb , Tim Jenness , Douglas Scott , Remo P. J. Tilanus , Frossie Economou , Wayne S. Holland

SCUBA-2, which replaces SCUBA (the Submillimeter Common User Bolometer Array) on the James Clerk Maxwell Telescope (JCMT) in 2006, is a large-format bolometer array for submillimeter astronomy. Unlike previous detectors which have used…

We explore novel methods of recovering the original spectral line profiles from data obtained by instruments that sample those profiles with an extended or multipeaked spectral transmission profile. The techniques are tested on data…

Solar and Stellar Astrophysics · Physics 2020-05-13 Momchil Molnar , Kevin Reardon , Christopher Osborne , Ivan Milić

We present the results of a multi-wavelength study of the 19 most significant sub-mm sources detected in the SCUBA 8-mJy survey. As described in Scott et al. (2001), this survey covers ~260 arcmin^2 using the sub-millimetre camera SCUBA, to…

We have detected the Sunyaev-Zel'dovich (SZ) increment at 850 microns in two galaxy clusters (Cl 0016+16 and MS 1054.4-0321) using SCUBA (Sub-millimetre Common User Bolometer Array) on the James Clerk Maxwell Telescope. Fits to the…

Wide-field sub-millimetre surveys have driven many major advances in galaxy evolution in the past decade, but without extensive follow-up observations the coarse angular resolution of these surveys limits the science exploitation. This has…

Astrophysics of Galaxies · Physics 2021-09-23 Lynge Lauritsen , Hugh Dickinson , Jane Bromley , Stephen Serjeant , Chen-Fatt Lim , Zhen-Kai Gao , Wei-Hao Wang

A method for spatial deconvolution of spectra is presented. It follows the same fundamental principles as the ``MCS image deconvolution algorithm'' (Magain, Courbin, Sohy, 1998) and uses information contained in the spectrum of a reference…

Astrophysics · Physics 2009-10-31 F. Courbin , P. Magain , M. Kirkove , S. Sohy

Light sheet fluorescence microscopy is able to image large specimen with high resolution by imaging the sam- ples from multiple angles. Multi-view deconvolution can significantly improve the resolution and contrast of the images, but its…

Quantitative Methods · Quantitative Biology 2014-12-03 Stephan Preibisch , Fernando Amat , Evangelia Stamataki , Mihail Sarov , Robert H. Singer , Eugene Myers , Pavel Tomancak

SCUBA-2 is the next-generation replacement for SCUBA (Sub-millimetre Common User Bolometer Array) on the James Clerk Maxwell Telescope. Operating at 450 and 850 microns, SCUBA-2 fills the focal plane of the telescope with fully-sampled,…

Instrumentation and Detectors · Physics 2009-11-10 Michael Audley , Giampaolo Pisano , Wayne Holland , William Duncan , William Parkes , Peter Ade

Recently, super-resolution ultrasound imaging with ultrasound localization microscopy (ULM) has received much attention. However, ULM relies on low concentrations of microbubbles in the blood vessels, ultimately resulting in long…

SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key…

SCUBA-2 is an innovative 10,000 pixel submillimeter camera due to be delivered to the James Clerk Maxwell Telescope in late 2006. The camera is expected to revolutionize submillimeter astronomy in terms of the ability to carry out…

Aims : We describe MS-MFS, a multi-scale multi-frequency deconvolution algorithm for wide-band synthesis-imaging, and present imaging results that illustrate the capabilities of the algorithm and the conditions under which it is feasible…

Instrumentation and Methods for Astrophysics · Physics 2015-05-28 Urvashi Rau , Tim J. Cornwell

We present 850um imaging of the XMM-LSS field observed for 170 hours as part of the James Clerk Maxwell Telescope SCUBA-2 Large eXtragalactic Survey (S2LXS). S2LXS XMM-LSS maps an area of 9 square degrees, reaching a moderate depth of…

‹ Prev 1 2 3 10 Next ›