Electrical impedance tomography (EIT) plays a crucial role in non-invasive imaging, with both medical and industrial applications. In this paper, we present three data-driven reconstruction methods for EIT imaging. These three approaches…

Image and Video Processing · Electrical Eng. & Systems 2024-07-03 Alexander Denker , Zeljko Kereta , Imraj Singh , Tom Freudenberg , Tobias Kluth , Peter Maass , Simon Arridge

Recent years have seen vast progress in the generation and detection of structured light, with potential applications in high capacity optical data storage and continuous variable quantum technologies. Here we measure the transmission of…

We show how to eliminate the error caused by an incorrectly modeled boundary in electrical impedance tomography (EIT). In practical measurements, one usually lacks the exact knowledge of the boundary. Because of this the numerical…

Analysis of PDEs · Mathematics 2007-05-23 Ville Kolehmainen , Matti Lassas , Petri Ola

This work extends the results of [Garde and Hyv\"onen, Math. Comp. 91:1925-1953] on series reversion for Calder\'on's problem to the case of realistic electrode measurements, with both the internal admittivity of the investigated body and…

Numerical Analysis · Mathematics 2023-07-19 Henrik Garde , Nuutti Hyvönen , Topi Kuutela

Magneto-acousto-electric tomography (MAET) combines ultrasound with a static magnetic field to infer the electrical conductivity of an object. In this paper, we present a rigorous quasi-static mathematical model for MAET with magnetic field…

Analysis of PDEs · Mathematics 2026-03-03 Lingyun Qiu , Siqin Zheng

We present an algorithm for focusing inversion of electrical resistivity tomography (ERT) data. ERT is a typical example of ill-posed problem. Regularization is the most common way to face this kind of problems; it basically consists in…

Geophysics · Physics 2007-05-23 G. Pagliara , G. Vignoli

We introduce a dual-wavelength Fourier ptychographic topography (FPT) method that extends the lambda/2 height-range limit of single-wavelength FPT. By reconstructing complex fields at two illumination wavelengths and exploiting their phase…

In recent years, particular physical phenomena enabled by non-Hermitian metamaterial systems have attracted significant research interests. In this paper, a non-Hermitian three-dimensional metamaterial near the exceptional point (EP) is…

Applied Physics · Physics 2024-01-24 Yanjie Wu , Ding Zhang , Qiuyu Li , Hai Lin , Xintong Shi , Jie Xiong , Haoquan Hu , Jing Tian , Bian Wu , Y. Liu

Thermoelastic distortion resulting from optical absorption by transmissive and reflective optics can cause unacceptable changes in optical systems that employ high power beams. In advanced-generation laser-interferometric gravitational wave…

Optics · Physics 2015-04-29 Eleanor King , Yuri Levin , David Ottaway , Peter Veitch

In a lot of systems, charge transport is governed by local features rather than being a global property as suggested by extracting a single resistance value. Consequently, techniques that resolve local structure in the electronic potential…

Central idea: To obtain the interaction potential using the inverse scattering method, we have employed the Physics-Informed Machine Learning (PIML) approach. In this framework, the machine learning algorithm is guided by the underlying…

An efficient computational approach for optimal reconstruction of binary-type images suitable for models in various applications including biomedical imaging is developed and validated. The methodology includes derivative-free optimization…

Optimization and Control · Mathematics 2022-09-27 Paul R. Arbic , Vladislav Bukshtynov

In this work, we demonstrate that the ptychographic phase problem can be solved in a live fashion during scanning, while data is still being collected. We propose a generally applicable modification of the widespread projection-based…

Image and Video Processing · Electrical Eng. & Systems 2023-09-20 Simon Welker , Tal Peer , Henry N. Chapman , Timo Gerkmann

Fiber-reinforced composites with nanofiller-modified polymer matrices have immense potential to improve the safety of high-risk engineering structures. These materials are intrinsically self-sensing because their electrical conductivity is…

Materials Science · Physics 2021-12-10 Hashim Hassan , Tyler N. Tallman

Photomultiplier tubes (PMTs) are widely employed in particle and nuclear physics experiments. The accuracy of PMT waveform reconstruction directly impacts the detector's spatial and energy resolution. A key challenge arises when multiple…

High Energy Physics - Experiment · Physics 2026-02-06 Kainan Liu , Jingyu Huang , Guihong Huang , Jianyi Luo

The inverse problem of electrical resistivity surveys (ERSs) is difficult because of its nonlinear and ill-posed nature. For this task, traditional linear inversion methods still face challenges such as suboptimal approximation and initial…

Computer Vision and Pattern Recognition · Computer Science 2020-06-29 Bin Liu , Qian Guo , Shucai Li , Benchao Liu , Yuxiao Ren , Yonghao Pang , Xu Guo , Lanbo Liu , Peng Jiang

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most…

Image and Video Processing · Electrical Eng. & Systems 2024-04-11 Yuchen Fei , Yanmei Luo , Yan Wang , Jiaqi Cui , Yuanyuan Xu , Jiliu Zhou , Dinggang Shen

A method is described for the reconstruction of the amplitude and phase of the object exit wave function by phase-plate transmission electron microscopy. The proposed method can be considered as in-line holography and requires three images,…

Materials Science · Physics 2017-05-24 B. Gamm , M. Dries , K. Schultheiss , H. Blank , A. Rosenauer , R. R. Schröder , D. Gerthsen

Compared with conventional single-energy computed tomography (CT), dual-energy CT (DECT) provides better material differentiation but most DECT imaging systems require dual full-angle projection data at different X-ray spectra. Relaxing the…

Thin-film transistors (TFTs) represent a wide-spread tool to determine the charge-carrier mobility of materials. Mobilities and further transistor parameters like contact resistances are commonly extracted from the electrical…