Related papers: A Compton polarimeter using scintillators read out…
We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on…
The performance of the $200\times2.5\times1$ cm$^3$ plastic scintillator strip with wavelength shifting fiber read-out by two novel photodetectors called Silicon PhotoMultipliers (SiPMs) is discussed. The advantages of SiPM relative to the…
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument…
Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and…
Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an…
We have measured the linear polarisation of hard X-ray emission from the Crab in a previously unexplored energy interval, 20-120 keV. The introduction of two new observational parameters, the polarisation fraction and angle stands to…
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…
We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03,…
Gamma-Ray Bursts are among the most powerful events in the Universe. Despite half a century of observations of these transient sources, many open questions remain about their nature. Polarization measurements of the GRB prompt emission have…
A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…
Over the next year, a new era of observations of compact objects in X-ray polarization will commence. Among the key targets for the upcoming Imaging X-ray Polarimetry Explorer mission, will be the magnetars 4U 0142+61 and 1RXS…
In this paper, we present development of a portable cosmic muon tracker tailored for both on-site measurements of cosmic muon flux as well as for outreach activities. The tracker comprises of two 70 mm x 70 mm plastic scintillators,…
Organic scintillators using a solid polyurethane (PU) matrix have been introduced to combine the robustness of a construction material with scintillating properties that allow gamma rays and fast neutrons to be detected efficiently and at…
In recent years, the field of radiation detection has witnessed a paradigm shift with the emergence of plastic scintillators incorporating perovskite nanocrystals (PNCs). This innovative class of scintillators not only capitalizes on the…
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it…
A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With…
Imaging hadronic calorimeters with scintillator readout use small scintillator tiles individually read out by silicon photomultipliers to achieve the necessary granularity needed for sophisticated reconstruction algorithms at future…
We constructed a gamma-ray detector by combining two types of scintillator array detectors with an MPPC array and evaluated the spectral performance by reading out the signals from the MPPC with a low-power integrated circuit (ASIC)…
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind…
We have studied the possibility of using Geiger mode multi-pixel photodiodes to read out long scintillator bars with a single wavelength-shifting fiber embedded along the bar. This detector configuration can be used in large volume…