English
Related papers

Related papers: New ion energy-mass spectrometer ULTIMAN (UlTImate…

200 papers

Ion energy measurements have been made in the scrape off layer of the Mega Amp Spherical Tokamak (MAST) using a midplane retarding field energy analyser (RFEA) in H-mode plasmas during the inter-edge localised mode (ELM) period and during…

Plasma Physics · Physics 2013-06-28 S. Y. Allan , S. Elmore , A. Kirk , M. Kočan , P. Tamain

A numerical study on ion acceleration in electrostatic shock waves is presented, with the aim of determining the best plasma configuration to achieve quasi-monoenergetic ion beams in laser-driven systems. It was recently shown that tailored…

Plasma Physics · Physics 2018-03-14 E. Boella , F. Fiúza , A. Stockem Novo , R. Fonseca , L. O. Silva

In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the…

Instrumentation and Detectors · Physics 2023-07-19 M. Rosenbusch , P. Schury , M. Wada , S. Iimura , Y. Ito , H. Wollnik

Recently, we reported an ion trap experiment with an integrated time-of-flight mass spectrometer (TOFMS) [Phys. Rev. Appl. 2, 034013 (2014)] focussing on the improvement of mass resolution and detection limit due to sample preparation at…

Atomic Physics · Physics 2016-01-20 Christian Schneider , Steven J. Schowalter , Peter Yu , Eric R. Hudson

A Computationally Assisted Spectroscopic Technique to measure secondary electron emission coefficients ($\gamma$-CAST) in capacitively-coupled radio-frequency plasmas is proposed. This non-intrusive, sensitive diagnostic is based on a…

Plasma Physics · Physics 2016-06-22 M. Daksha , B. Berger , E. Schuengel , I. Korolov , A. Derzsi , M. Koepke , Z. Donko , J. Schulze

We demonstrate a Wiley-McClaren Time of Flight Mass Spectrometer modified to allow direct extraction of ions from a laser-induced plasma. Unlike many other methods that utilize mass spectrometry to investigate laser-induced plasmas, no…

Plasma Physics · Physics 2020-10-21 James O. F. Thompson , S. Tahereh Alavi , Justin R. Walensky , Arthur G. Suits

We describe a spin-resolved electron spectrometer capable of uniquely efficient and high energy resolution measurements. Spin analysis is obtained through polarimetry based on low-energy exchange scattering from a ferromagnetic thin-film…

Materials Science · Physics 2014-11-21 C. Jozwiak , J. Graf , G. Lebedev , N. Andresen , A. K. Schmid , A. V. Fedorov , F. El Gabaly , W. Wan , A. Lanzara , Z. Hussain

A new method for measuring the electron temperature of the plasma in GOL-NB facility is proposed. The proposed method is based on measuring the ratio of intensities of spectral lines emitted by fast atoms injected into the plasma. The beams…

Plasma Physics · Physics 2023-07-31 S. Polosatkin

A novel room-temperature ion source for the production of atomic ions in electron beam within wide ranges of electron energy and current density is developed. The device can operate both as conventional Electron Beam Ion Source/Trap…

Plasma Physics · Physics 2017-04-05 V. P. Ovsyannikov , A. V. Nefiodov , A. A. Levin

High-resolution tunable laser spectroscopy is used to measure time-resolved absorption spectra for ten neutral uranium transitions and six singly-ionized transitions in a laser produced plasma. Spectral lineshapes are analyzed to determine…

The advent of the quantum gas microscope allowed for the in situ probing of ultracold gaseous matter on an unprecedented level of spatial resolution. The study of phenomena on ever smaller length scales as well as the probing of…

Atomic Physics · Physics 2021-02-24 C. Veit , N. Zuber , O. A. Herrera-Sancho , V. S. V. Anasuri , T. Schmid , F. Meinert , R. Löw , T. Pfau

Energy-transfer efficiency is an important quantity in plasma-wakefield acceleration, especially for applications that demand high average power. Conventionally, the efficiency is measured using an electron spectrometer; an invasive method…

Previous experiments on MAST and other tokamaks have indicated that the level of fast ion redistribution can exceed that expected from classical diffusion and that this level increases with beam power. In this paper we present a…

Ion sources using electron impact ionization (EI) methods have been widely accepted in mass spectrometry for planetary exploration missions because of their simplicity. Previous space-borne mass spectrometers were primarily designed with…

Within the problem of the finding of the mean potential energy of the charged particle in the plasma in this work a classification of physical systems (electrolytes, dusty plasmas, plasmas) is made based on consideration, or lack thereof,…

Plasma Physics · Physics 2017-03-23 A. A. Mihajlov , Lj. M. Ignjatovic , V. A. Sreckovic

We present the development and performance of a newly built recoil ion momentum spectrometer to study the fragmentation dynamics of ionized molecules. The spectrometer is based on the two-stage Wiley-McLaren geometry and satisfies both time…

Atomic Physics · Physics 2022-11-23 Avijit Duley , Rohit Tyagi , Sandeep B. Bari , A. H. Kelkar

We report optical absorption imaging of ultracold neutral plasmas.Images are used to measure the ion absorption spectrum, which is Doppler-broadened. Through the spectral width, we monitor ion equilibration in the first 250ns after plasma…

Atomic Physics · Physics 2009-11-10 C. E. Simien , Y. C. Chen , P. Gupta , S. Laha , Y. N. Martinez , P. G. Mickelson , S. B. Nagel , T. C. Killian

Measurements are reported of electromagnetic emission close to the cyclotron frequency of energetic ions in JET plasmas heated by waves in the ion cyclotron range of frequencies (ICRF). Hydrogen was the majority ion species in all of these…

The knowledge of absolute fluxes of reactive species such as radicals or energetic ions to the surface is crucial for understanding the growth or etching of thin films. These species have due to their high reactivity very low densities and…

Plasma Physics · Physics 2011-05-16 Jan Benedikt , Dirk Ellerweg , Achim von Keudell

The paper presents a detailed description of a neutral particle analyzer designed and produced for plasma diagnostics on the spherical tokamak ST40. The aim of the diagnostic is to measure both the bulk ion temperature in the range from 0.5…

Plasma Physics · Physics 2025-02-20 Sergey Polosatkin , Vasily Belykh , Andrey Rovenskikh