Related papers: Conclusive nonlinear phase sensitivity limit for a…
Phase measurement using a lossless Mach-Zehnder interferometer with certain entangled $N$-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are…
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input…
We show that the phase sensitivity $\Delta \theta$ of a Mach-Zehnder interferometer fed by a coherent state in one input port and squeezed-vacuum in the other one is i) independent from the true value of the phase shift and ii) can reach…
The best performance of a Mach-Zehnder interferometer is achieved with the input state |N_T/2 + 1>|N_T/2-1 > + |N_T/2 - 1>|N_T/2+1>, being N_T the total number of atoms/photons. This gives: i) a phase-shift error confidence C_{68%}=2.67/N_T…
We provide general bounds of phase estimation sensitivity in linear two-mode interferometers. We consider probe states with a fluctuating total number of particles. With incoherent mixtures of state with different total number of particles,…
We theoretically analyze a Mach-Zehnder interferometer with trapped condensates, and find that it is surprisingly stable against the nonlinearity induced by inter-particle interactions. The phase sensitivity, which we study for number…
The canonical Mach-Zehnder interferometer fed with a coherent state and a squeezed-vacuum state of equal intensities is theoretically predicted to achieve Heisenberg scaling in phase sensitivity. However, this ultimate performance is…
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a thermal state and squeezed vacuum state as inputs and parity detection as measurement. We find that phase sensitivity can beat the shot-noise limit and…
We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in…
We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon…
We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently…
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The…
We investigate the phase sensitivity of a Mach-Zehnder interferometer using a special class of generalized coherent states constructed from generalized Heisenberg and deformed $su(1,1)$ algebras. These states, derived from a perturbed…
Two path interferometry with coherent states and squeezed vacuum can achieve phase sensitivities close to the Heisenberg limit when the average photon number of the squeezed vacuum is close to the average photon number of the coherent…
Bose Einstein Condensates, with their coherence properties, have attracted wide interest for their possible application to ultra precise interferometry and ultra weak force sensors. Since condensates, unlike photons, are interacting, they…
We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We…
We study the sensitivity of a Mach-Zehnder interferometer that contains in addition to the phase shifter a non-linear element. By including both elements in a cavity or a loop that the light transverses many times, a non-linear kicked…
Achieving the ultimate quantum precision in the estimation of multiple physical parameters simultaneously is a challenge in quantum metrology due to fundamental limitations and experimental challenges in harnessing the necessary quantum…
Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The…
The ultimate precision of phase estimation is limited by the Heisenberg scaling $\Delta\phi_0 = K/N$, where $K\sim1$ is a numerical prefactor and $N$ is the mean number of photons interacting with the phase shifting object(s). However,…