Contrast resolution beyond the limits of conventional cone-beam CT (CBCT) systems is essential to high-quality imaging of the brain. We present a deep learning reconstruction method (dubbed DL-Recon) that integrates physically principled…

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

Applying standard algorithms to sparse data problems in photoacoustic tomography (PAT) yields low-quality images containing severe under-sampling artifacts. To some extent, these artifacts can be reduced by iterative image reconstruction…

Numerical Analysis · Mathematics 2024-12-20 Stephan Antholzer , Johannes Schwab , Robert Nuster , Markus Haltmeier

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

Image and Video Processing · Electrical Eng. & Systems 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

This paper presents a new method for reconstructing regions of interest (ROI) from a limited number of computed tomography (CT) measurements. Classical model-based iterative reconstruction methods lead to images with predictable features.…

Image and Video Processing · Electrical Eng. & Systems 2023-05-18 Marion Savanier , Emilie Chouzenoux , Jean-Christophe Pesquet , Cyril Riddell

Industrial X-ray cone-beam CT (XCT) scanners are widely used for scientific imaging and non-destructive characterization. Industrial CBCT scanners use large detectors containing millions of pixels and the subsequent 3D reconstructions can…

Image and Video Processing · Electrical Eng. & Systems 2025-01-24 Aniket Pramanik , Singanallur V. Venkatakrishnan , Obaidullah Rahman , Amirkoushyar Ziabari

We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…

Computer Vision and Pattern Recognition · Computer Science 2018-12-11 Haofu Liao , Zhimin Huo , William J. Sehnert , Shaohua Kevin Zhou , Jiebo Luo

Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw…

Image and Video Processing · Electrical Eng. & Systems 2024-10-01 Ziheng Deng , Hua Chen , Yongzheng Zhou , Haibo Hu , Zhiyong Xu , Jiayuan Sun , Tianling Lyu , Yan Xi , Yang Chen , Jun Zhao

Computed Tomography (CT) is widely used in healthcare for detailed imaging. However, Low-dose CT, despite reducing radiation exposure, often results in images with compromised quality due to increased noise. Traditional methods, including…

Image and Video Processing · Electrical Eng. & Systems 2024-09-17 Herman Verinaz-Jadan , Su Yan

Unlike previous works, this open data collection consists of X-ray cone-beam (CB) computed tomography (CT) datasets specifically designed for machine learning applications and high cone-angle artefact reduction. Forty-two walnuts were…

Image and Video Processing · Electrical Eng. & Systems 2020-09-07 Henri Der Sarkissian , Felix Lucka , Maureen van Eijnatten , Giulia Colacicco , Sophia Bethany Coban , Kees Joost Batenburg

Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A…

Image and Video Processing · Electrical Eng. & Systems 2020-07-06 Ilkay Oksuz , James R. Clough , Bram Ruijsink , Esther Puyol Anton , Aurelien Bustin , Gastao Cruz , Claudia Prieto , Andrew P. King , Julia A. Schnabel

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

Medical Physics · Physics 2016-04-07 Shi-peng Xie , Rui-ju Yan

Limited-angle computerized tomography stands for one of the most difficult challenges in imaging. Although it opens the way to faster data acquisition in industry and less dangerous scans in medicine, standard approaches, such as the…

Image and Video Processing · Electrical Eng. & Systems 2025-10-07 Bernadette Hahn , Gael Rigaud , Richard Schmähl

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

Computer Vision and Pattern Recognition · Computer Science 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Due to the potential risk of inducing cancers, radiation dose of X-ray CT should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts usually occur due to photon starvation, beamhardening, etc, which…

Computer Vision and Pattern Recognition · Computer Science 2018-02-07 Eunhee Kang , Junhong Min , Jong Chul Ye

Reconstruction of few-view x-ray Computed Tomography (CT) data is a highly ill-posed problem. It is often used in applications that require low radiation dose in clinical CT, rapid industrial scanning, or fixed-gantry CT. Existing analytic…

Image and Video Processing · Electrical Eng. & Systems 2019-10-15 Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley

Inspired by the success of deep learning applications on restoration of low-dose and sparse CT images, we propose a novel method to reconstruct high-quality 4D cone-beam CT (4DCBCT) images from sparse datasets. Our approach combines the…

Medical Physics · Physics 2018-08-14 Joel Beaudry , Pedro L. Esquinas

In dental cone-beam computed tomography (CBCT), compact and cost-effective system designs often use small detectors, resulting in a truncated field of view (FOV) that does not fully encompass the patient's head. In iterative reconstruction…

Computer Vision and Pattern Recognition · Computer Science 2025-08-12 Hyoung Suk Park , Kiwan Jeon

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

Computer Vision and Pattern Recognition · Computer Science 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

Helical CT has been widely used in clinical diagnosis. Sparsely spaced multidetector in z direction can increase the coverage of the detector provided limited detector rows. It can speed up volumetric CT scan, lower the radiation dose and…

Medical Physics · Physics 2019-10-24 Ao Zheng , Hewei Gao , Li Zhang , Yuxiang Xing