Related papers: High voltage scheme optimization for secondary dis…
The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the…
We develop two inverse scattering schemes for locating multiple electromagnetic (EM) scatterers by the electric far-field measurement corresponding to a single incident/detecting plane wave. The first scheme is for locating scatterers of…
The Gas Electron Multiplier (GEM) is a new age detector, which can handle the high flux of particles. The GEM foil, which is constructed using 50$\mu$m highly insulating foil (Kapton/Apical) coated with 5$\mu$m layers of copper, on both…
This works reports on gaseous detectors developments made in the frame of the EXO double-beta decay experiment. LEM (Large Electron Multiplication) are electron amplification grids based on GEM. They were developed in Neuchatel and showed…
The triple GEM detector is a micropattern gas detector which consists of a primary ionisation gap and three consecutive gas electron multiplier (GEM) foils. A printed circuit board with readout strips detects the current induced by the…
The multi-phase inverter has become more complicated, particularly in an Electric Vehicle (EV)'s power train, which requires a robust fault protection system. The proposed active short circuit and safe discharge mechanisms are also included…
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…
A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of…
A method is proposed to dump the spurious signals induced by fluorescence of the electrodes in gaseous detectors under strong X-Ray irradiation, introducing a special fluorescence suppressor electrode between the sensitive and the…
We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…
The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime…
We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…
Resonant inductive coupling is commonly seen as an undesired fundamental phenomenon emergent in densely packed resonant structures, such as nuclear magnetic resonance phased array detectors. The need to mitigate coupling imposes rigid…
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron…
Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…
We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining…
Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…