Related papers: Source Shot Noise Mitigation in Focused Ion Beam M…

200 papers

In a focused ion beam (FIB) microscope, source particles interact with a small volume of a sample to generate secondary electrons that are detected, pixel by pixel, to produce a micrograph. Randomness of the number of incident particles…

Medical Physics · Physics 2023-08-15 Minxu Peng , John Murray-Bruce , Vivek K Goyal

Modern science is dependent on imaging on the nanoscale, often achieved through processes that detect secondary electrons created by a highly focused incident charged particle beam. Multiple types of measurement noise limit the ultimate…

Particle beam microscopy (PBM) performs nanoscale imaging by pixelwise capture of scalar values representing noisy measurements of the response from secondary electrons (SEs) integrated over a dwell time. Extended to metrology, goals…

Data Analysis, Statistics and Probability · Physics 2023-08-15 Akshay Agarwal , Minxu Peng , Vivek K. Goyal

We propose a modified moment matching algorithm to avoid catastrophic failures for sources with a low signal to noise ratio (SNR). The proposed modifications include a method to eliminate non-physical negative pixel values and a forced…

Instrumentation and Methods for Astrophysics · Physics 2025-02-04 Anirban Dutta , John R. Peterson , Glenn Sembroski

A promising result from optical quantum metrology is the ability to achieve sub-shot-noise performance in transmission or absorption measurements. This is due to the significantly lower uncertainty in light intensity of quantum beams with…

Quantum Physics · Physics 2021-09-01 Agustina G. Magnoni , Laura T. Knoll , Miguel A. Larotonda

For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-18 Jun Zhang , Wentao Luo , Sebastien Foucaud

Secondary electron (SE) imaging techniques, such as scanning electron microscopy and helium ion microscopy (HIM), use electrons emitted by a sample in response to a focused beam of charged particles incident at a grid of raster scan…

Signal Processing · Electrical Eng. & Systems 2026-03-12 Vaibhav Choudhary , Akshay Agarwal , Vivek K Goyal

Focused ion beams (FIBs) are widely used in nanofabrication for applications such as circuit repair, ultra-thin lamella preparation, strain engineering, and quantum device prototyping. Although the lateral spread of the ion beam is often…

Instrumentation and Detectors · Physics 2025-11-04 M. G. Masteghin , Z. P. Aslam , A. P. Brown , M. J. Whiting , S. K. Clowes , R. P. Webb , D. C. Cox

Particle beam microscopy uses a scanning beam of charged particles to create images of samples, and the quality of image reconstruction suffers when this beam current varies over time. Neither conventional reconstruction methods nor…

Image and Video Processing · Electrical Eng. & Systems 2021-06-10 Luisa Watkins

Time-resolved atom interferometry, as employed in applications such as gravitational wave detection and searches for ultra-light dark matter, requires precise control over systematic effects. In this work, we investigate phase noise arising…

Atomic Physics · Physics 2025-11-25 Noam Mouelle , Jeremiah Mitchell , Valerie Gibson , Ulrich Schneider

This is a review of shot noise, the time-dependent fluctuations in the electrical current due to the discreteness of the electron charge, in small conductors. The shot-noise power can be smaller than that of a Poisson process as a result of…

Mesoscale and Nanoscale Physics · Physics 2008-02-03 M. J. M. de Jong , C. W. J. Beenakker

Microscope mode imaging for secondary ion mass spectrometry is a technique with the promise of simultaneous high spatial resolution and high speed imaging of biomolecules from complex surfaces. Technological developments such as new…

Instrumentation and Detectors · Physics 2013-09-05 András Kiss , Donald F. Smith , Julia H. Jungmann , Ron M. A. Heeren

This study presents a detailed examination of the lattice distortions introduced by glancing incidence Focussed Ion Beam (FIB) milling. Using non-destructive multi-reflection Bragg coherent X-ray diffraction we probe damage formation in an…

Materials Science · Physics 2017-11-29 Felix Hofmann , Ross J. Harder , Wenjun Liu , Yuzi Liu , Ian K Robinson , Yevhen Zayachuk

A new methodology for fundamental studies of radiation effects in solids is herein introduced by using a plasma Focused Ion Beam (PFIB). The classical example of ion-induced amorphization of single-crystalline pure Si is used as a…

Materials Science · Physics 2022-09-09 M. A. Tunes , M. M. Schneider , C. A. Taylor , T. A. Saleh

Current fluctuations related to the discreteness of charge passing through small constrictions are termed shot noise. This unavoidable noise provides both advantages - being a direct measurement of the transmitted particles' charge, and…

Mesoscale and Nanoscale Physics · Physics 2022-04-06 Idan Tamir , Verena Caspari , Daniela Rolf , Christian Lotze , Katharina J. Franke

We realize a single particle microscope by using deterministically extracted laser cooled $^{40}$Ca$^+$ ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions with a resolution of…

Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the…

Quantum Physics · Physics 2020-08-26 Jason D. Mueller , Nigam Samantaray , Jonathan C. F. Matthews

We analyze noise in a quantum-enhanced fiber optic gyroscope (FOG), focusing on one of the leading sources of phase uncertainty - uncorrelated photon saturation. Taking a squeezed state input as a source for N00N states, we compute the…

Quantum Physics · Physics 2026-03-27 Stefan Evans , Joanna Ptasinski

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently…

Focused ion beam (FIB) technology has been used to fabricate miniature Nb DC SQUIDs which incorporate resistively-shunted microbridge junctions and a central loop with a hole diameter ranging from 1058 nm to 50 nm. The smallest device, with…

Superconductivity · Physics 2010-03-30 Giuseppe C. Tettamanzi , Christopher I. Pakes , Simon K. H. Lam , Steven Prawer