Scientific detectors are a key technological enabler for many disciplines. Application-specific integrated circuits (ASICs) are used for many of these scientific detectors. Until recently, pixel detector ASICs have been used mainly for…

Instrumentation and Detectors · Physics 2021-10-18 Sebastian Strempfer , Kazutomo Yoshii , Mike Hammer , Dawid Bycul , Antonino Miceli

The D-band, spanning 110 GHz to 170 GHz, has emerged as a relevant frequency range for future mobile communications and radar sensing applications, particularly in the context of 6G technologies. This demonstration presents a…

Signal Processing · Electrical Eng. & Systems 2024-07-09 Sven Wittig , Rodrigo Hernangomez , Karen Vardanyan , Ramez Askar , Amr Haj-Omar , Michael Peter , Slawomir Stanczak

Synchrotron radiation light sources produce intense beam of X-ray with ultra-short pulse and nanosecond period. This of-fers the opportunities for the time resolution experiments. Achieving higher counting rate and faster arriving time is…

Instrumentation and Detectors · Physics 2015-11-05 Zhen-jie Li , Qiu-ju Li , Peng Liu , Shan-feng Wang , Wei-wei Dong , Yang-fan Zhou

We have developed two radiation-hard ASICs for optical data transmission in the ATLAS pixel detector at the LHC at CERN: a driver chip for a Vertical Cavity Surface Emitting Laser (VCSEL) diode for 80 Mbit/s data transmission from the…

Instrumentation and Detectors · Physics 2017-08-23 K. K. Gan

We present the optimization and performance characterization of the second-generation Fermilab Constant Fraction Discriminator ASIC (FCFD), designed for the readout of AC-coupled low-gain avalanche detector (LGAD) strip-sensors. The FCFD is…

Instrumentation and Detectors · Physics 2025-12-24 Artur Apresyan , Shuoxing Wu , Si Xie , Cristián Peña , Tom Zimmerman , Sergey Los , Todd Zenger , Zhenyu Ye

The Focusing Optics X-ray Solar Imager (FOXSI) is a NASA sounding rocket mission which will study particle acceleration and coronal heating on the Sun through high sensitivity observations in the hard X-ray energy band (5-15 keV). Combining…

The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The…

Instrumentation and Detectors · Physics 2017-06-07 Jayanth Kuppambatti , Jaroslav Ban , Timothy Andeen , Rex Brown , Ryne Carbone , Peter Kinget , Gustaaf Brooilmans , William Sippach

Radiation measurement relies on pulse detection, which can be performed using various configurations of high-speed analog-to-digital converters (ADCs) and field-programmable gate arrays (FPGAs). For optimal power consumption, design…

We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for…

High-granularity calorimeters utilizing silicon pad sensors as main active material are being designed for the CMS endcap calorimeter upgrade and have been proposed for the electromagnetic calorimeters at CLIC, ILC and FCC-ee. The silicon…

Instrumentation and Detectors · Physics 2020-08-26 Pedro Dias de Almeida

.On the basis of requirement of CSNS, we designed a TDC chip with temperature compensation function in this paper, which employed TSMC 180nm process. Using delay unit bufx8 as the major method, delay lines in each level delayed input signal…

Instrumentation and Detectors · Physics 2018-06-27 Yichao Ma , Xinyang Hong , Jian Zhuang , Zhijia Sun , Yafan Tao , Yongsheng Shi , Jianrong Zhou

The demand for energy-efficient and high performance embedded systems drives the evolution of new hardware architectures, including concepts like approximate computing. This paper presents a novel reconfigurable embedded platform named…

Hardware Architecture · Computer Science 2024-10-02 Arvin Delavari , Faraz Ghoreishy , Hadi Shahriar Shahhoseini , Sattar Mirzakuchaki

In this paper, we present a dual-channel serializer ASIC, LOCx2, and its pin-compatible backup, LOCx2-130, for detector front-end readout. LOCx2 is fabricated in a 0.25-um Silicon-on-Sapphire CMOS process and each channel operates at 5.12…

For experiments at the European X-Ray Free-Electron Laser (XFEL) the Adaptive Gain Integrating Pixel Detector (AGIPD) is under development. The particular requirements for the detector are a high dynamic range of 0, 1 - to more than 10E4…

Instrumentation and Detectors · Physics 2015-06-11 J. Schwandt , E. Fretwurst , R. Klanner , J. Zhang

Advances in miniaturised implantable neural electronics have paved the way for therapeutic brain-computer interfaces with clinical potential for movement disorders, epilepsy, and broader neurological applications. This paper presents a…

Signal Processing · Electrical Eng. & Systems 2026-03-31 Dimitris Antoniadis , Timothy G. Constandinou

Some applications require electronic systems to operate at extremely high temperature. Extending the operating temperature range of automotive-grade CMOS processes -- through the use of dedicated design techniques -- can provide an…

Signal Processing · Electrical Eng. & Systems 2025-01-03 Christian Sbrana , Alessandro Catania , Tommaso Toschi , Sebastiano Strangio , Giuseppe Iannaccone

We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud…

The European X-ray Free Electron Laser (XFEL.EU) will provide every 0.1 s a train of 2700 spatially coherent ultrashort X-ray pulses at 4.5 MHz repetition rate. The Small Quantum Systems (SQS) instrument and the Spectroscopy and Coherent…

High-fidelity control of the thousands to millions of programmable qubits needed for utility-scale quantum computers presents a formidable challenge for control systems. In leading atomic systems, control is optical: UV-NIR beams must be…

Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and…