Related papers: Detector Technologies for CLIC
This report describes the exploration of fundamental questions in particle physics at the energy frontier with a future TeV-scale e+e- linear collider based on the Compact Linear Collider (CLIC) two-beam acceleration technology. A…
The Compact Linear Collider (CLIC) is a mature option for the future of high energy physics. It combines the benefits of the clean environment of $e^+e^-$ colliders with operation at high centre-of-mass energies, allowing to probe scales…
CLICdp, the CLIC detector and physics study, is an international collaboration presently composed of 23 institutions. The collaboration is addressing detector and physics issues for the future Compact Linear Collider (CLIC), a high-energy…
The Compact Linear Collider (CLIC) is a concept for a future $e^{+}e^{-}$ linear collider with a center-of-mass energy of up to 3 TeV. The design of a CLIC experiment is driven by the requirements related to the physics goals, as well as by…
The Compact Linear Collider (CLIC) is a mature option for a future electron-positron collider operating at centre-of-mass energies of up to 3 TeV. CLIC will be built and operated in a staged approach with three centre-of-mass energies…
The Compact Linear Collider (CLIC) is a proposed high-luminosity linear electron-positron collider at the energy frontier. It is foreseen to be built and operated in three stages, with a centre-of-mass energy ranging from a few hundred GeV…
This document provides input from the CLIC e+e- linear collider studies to the update process of the European Strategy for Particle Physics. It is submitted on behalf of the CLIC/CTF3 collaboration and the CLIC physics and detector study.…
The International Linear Collider (ILC) and the Compact Linear Collider (CLIC) are the two options for a future high-energy, high-luminosity linear electron-positron collider. Both are expected to be built in stages, optimised for their…
The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…
This contribution to LCWS2016 presents recent developments within the CLICdp collaboration. An updated scenario for the staged operation of CLIC has been published; the accelerator will operate at 380 GeV, 1.5 TeV and 3 TeV. The lowest…
The Compact Linear Collider (CLIC) is a proposed TeV-scale high-luminosity electron-positron collider at CERN. The first CLIC running stage, at 380\,GeV, will focus on precision Higgs boson and top quark studies while the main aim of the…
This report summarizes a study of the physics potential of the CLIC e+e- linear collider operating at centre-of-mass energies from 1 TeV to 5 TeV with luminosity of the order of 10^35 cm^-2 s^-1. First, the CLIC collider complex is…
The physics aims at the proposed high-energy $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. Precise hit-time tagging, an excellent spatial resolutions, and a low mass are required for the vertex…
The Compact Linear Collider, CLIC, is a multi-TeV electron-positron collider proposed for construction at CERN. A detector model, CLICdet, that is suited for the experimental conditions at CLIC and is based on realistic performance, has…
The Compact Linear Collider (CLIC) was proposed as the next energy-frontier infrastructure at CERN, to study e$^+$e$^-$ collisions at three centre-of-mass energy stages: 380 GeV, 1.5 TeV and 3 TeV. The main goal of its high-energy stages is…
Conformal tracking is an innovative track finding strategy adopted for the detector at the Compact Linear Collider (CLIC), a proposed future electron-positron collider. It features a pattern recognition in a conformal-mapped plane using the…
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy…
CLICTD is a monolithic silicon pixel sensor fabricated in a modified 180 nm CMOS imaging process with a small collection electrode design and a high-resistivity epitaxial layer. It features an innovative sub-pixel segmentation scheme and is…
A detector concept based on hybrid planar pixel-detector technology is under development for the CLIC vertex detector. It comprises fast, low-power and small-pitch readout ASICs implemented in 65 nm CMOS technology (CLICpix) coupled to…
The CLIC Study that aims at a linear collider able to deliver e+e- collisions at centre-of-mass energies up to 5 TeV with luminosity of 10^35 cm^-2 s^-1 is presented. Its physics potential is outlined with special emphasis to the…