Related papers: Linearized and Compensated Interferometric System …
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference…
We have developed a method to equip homodyne interferometers with the capability to operate with constant high sensitivity over many fringes for continuous real-time tracking. The method can be considered as an extension of the "J_1...J_4"…
Linear Collider Alignment and Survey (LiCAS) R&D group is proposing a novel automated metrology instrument dedicated to align and monitor the mechanical stability of a future linear high energy e+e- collider. LiCAS uses Laser Straightness…
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an…
Recent experiments in cosmology, particularly those aimed at detecting the faint, redshifted, global 21 cm hydrogen line (depth < ~200 mK, z > 7.5), have imposed stringent new requirements on radiometer calibration. In this work, we present…
Atom interferometers offer excellent sensitivity to gravitational and inertial signals but have limited dynamic range. We introduce a scheme that improves on this trade-off by a factor of 50 using composite fringes, obtained from sets of…
The rapid evolution of wearable technologies, such as AR glasses, demands compact, energy-efficient sensors capable of high-precision measurements in dynamic environments. Traditional Frequency-Modulated Continuous Wave (FMCW) Laser…
This paper presents experimental results that allow for the performance evaluation of a straight-line reference alignment system based on pseudo-nondiffracting Layer beams. Sensors, developed specifically for this system, feature four…
Operating atom-interferometer gyroscopes outside a laboratory environment is challenging primarily owing to the instability of laser systems. To enhance the thermal stability of free-space laser systems, a compact laser system using fiber…
We experimentally demonstrate a novel interferometric architecture for next-generation gravity missions, featuring a laser ranging interferometer (LRI) that enables monoaxial transmission and reception of laser beams between two optical…
An interferometric imaging technique has been proposed to instantly measure the diameter of individual spherical dust particles suspended in a gas discharge plasma. The technique is based on the defocused image analysis of both spherical…
The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known…
We present the design, bench-top setup, and experimental results of a compact heterodyne interferometer that achieves picometer-level displacement sensitivities in air over frequencies above 100 mHz. The optical configuration with spatially…
This paper presents a novel heterodyne grating interferometer designed to meet the precise measurement requirements of next-generation lithography systems and large-scale atomic-level manufacturing. Utilizing a dual-frequency light source,…
By reentering into laser interferometers, scattered or stray light introduces non-linear noise. This is a major limitation of precision interferometers as preventing such parasitic light is nearly impossible. Thus, substantial effort is put…
We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…
In this article, we describe the key features of the recently completed technical design for the International Linear Collider (ILC), a 200-500 GeV linear electron-positron collider (expandable to 1 TeV) that is based on 1.3 GHz…
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the…
The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately…
A high-resolution, intratrain position feedback system has been developed to achieve and maintain collisions at the proposed future electron-positron International Linear Collider (ILC). A prototype has been commissioned and tested with a…