Related papers: The Muon $g-2$ experiment at Fermilab
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory. The most recent measurement, performed at Brookhaven National Laboratory and completed…
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…
A new measurement of the magnetic anomaly $a_{\mu}$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times…
The $g-2$ experiment successfully completed its second data taking period (Run-2) between March and July 2019, with the analysis of Run-1 and Run-2 data currently proceeding. The final goal of the experiment is to determine the muon…
This White Paper briefly reviews the present status of the muon (g-2) Standard-Model prediction. This value results in a 3 - 4 standard-deviation difference with the experimental result from Brookhaven E821. The present experimental…
The Muon g-2 experiment at Fermilab, with the aim to measure the muon anomalous magnetic moment to an unprecedented level of 140~ppb, has started beam and detector commissioning in Summer 2017. To deal with incoming data projected to be…
We review the status of the anomalous magnetic moment of the muon as a precision probe of physics beyond the Standard Model (SM) after the release of the final results from the Fermi National Accelerator Laboratory (FNAL) Muon $g-2$…
The magnetic moment is a fundamental property of particles. The measurement of these magnetic moments and the comparison with the values predicted by the standard model of particle physics is a way to test our understanding of the…
The status of the muon (g-2) experiment at the Brookhaven AGS is reviewed. An accuracy of 1.3 ppm on the mu^+ anomalous magnetic moment has been achieved and published. This result differs with the standard model prediction by about 2.5…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a…
We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$…
The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the…
Anomalous magnetic moment of the muon, $a_{\mu}=(g_{\mu}-2)/2$, is one of the most precisely measured quantities in particle physics and it provides a stringent test of the Standard Model. The planned improvements of the experimental…
The new measurement of the muon's anomalous magnetic moment released by the Muon g-2 experiment at Fermilab sets strong constraints on the properties of many new particles. Using an effective field theory approach to the interactions of…
The muon g-2 collaboration has measured the anomalous magnetic g value of the positive muon to within a relative uncertainty of 0.7 parts per million. The result, a_{\mu^+} = 11 659 204(7)(5) x 10^{-10} is in good agreement with the…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
The Muon g-2/EDM Experiment at J-PARC will employ a novel way to measure the muon magnetic anomaly, a_mu = (g-2)_mu/2, by using a low-emittance beam of positive muons stored in a compact muon storage magnet. The experimental method includes…
Precision measurements of fundamental quantities have played a key role in pointing the way forward in developing our understanding of the universe. Though the enormously successful Standard Model (SM) describes the breadth of both…