This paper provides a detailed investigation of voltage ride-through in large loads, such as Artificial Intelligence data centers. Voltage ride-through capability of large loads during transient disturbances in the power grid is important…

Systems and Control · Electrical Eng. & Systems 2026-05-04 Amir Norouzi , Michael Morel

With steadily increasing wind turbine penetration, regulatory standards for grid interconnection are evolving to require that wind generation systems ride-through disturbances such as faults and support the grid during such events.…

Systems and Control · Electrical Eng. & Systems 2022-01-25 Patrick S Flannery , Giri Venkataramanan

This paper addresses the problem of controlling a variable-speed wind turbine with a Doubly Fed Induction Generator (DFIG), modeled as an electromechanically-coupled nonlinear system with rotor voltages and blade pitch angle as its inputs,…

Optimization and Control · Mathematics 2010-08-10 Yi Guo , S. Hossein Hosseini , John N. Jiang , Choon Yik Tang , Rama G. Ramakumar

In the transient stability analysis of renewable energy grid-tied systems, although a large amount of works have devoted to the detailed electromagnetic transient simulation and the stability analyses of during-fault stage, the whole…

Systems and Control · Electrical Eng. & Systems 2025-03-25 Hongsheng Xu , Meng Zhan

Data center loads have expanded significantly in recent years. Compared to traditional loads, data centers are highly sensitive to voltage deviations and thus their protection mechanisms trip more proactively during voltage fluctuations.…

Systems and Control · Electrical Eng. & Systems 2025-10-07 Yiheng Xie , Wenqi Cui , Adam Wierman

The phase-locked loop (PLL) used in the doubly fed induction generator (DFIG) can cause frequency coupling phenomena, which will give negative resistance characteristics ofthe DFIG at low frequency, resulting in stability issues under weak…

Systems and Control · Electrical Eng. & Systems 2023-07-20 Xiaoling Xiong , Bochen Luo , Longcan Li , Ziming Sun , Frede Blaabjerg

Wind generation is expected to reach substantially higher levels of penetration in the near future. With the converter interface, the rotor inertia of doubly-fed induction generator (DFIG) based wind turbine generator is effectively…

Systems and Control · Computer Science 2017-12-19 Siqi Wang , Kevin Tomsovic

This paper presents a sub-switching period current-limiting control for a grid-tied inverter to prevent transient overcurrents during grid faults and enable seamless fault ride-through (FRT). Sudden grid-voltage disturbances, such as…

Systems and Control · Electrical Eng. & Systems 2026-01-08 Jaeyeon Park , Jiyu Lee , Junyeol Maeng , Shenghui Cui

The displacement of synchronous generators by converter-interfaced renewable energy sources obliges wind farms to provide inertia, damping, and voltage support, above all in increasingly weak grid conditions. This paper presents a…

Systems and Control · Electrical Eng. & Systems 2025-10-07 Javier Garcia-Aguilar , Aurelio Garcia-Cerrada , Juan L. Zamora , Emilio Bueno , Elena Saiz , Almudena Muñoz-Babiano , Mohammad E. Zarei

Volt-VAr control is a popular method for mitigating overvoltage violations caused by high penetration of distributed energy resources (DERs) in distribution feeders. An inherent limitation of volt-VAr control is that the reactive power (Q)…

Systems and Control · Electrical Eng. & Systems 2024-05-29 Madhura Sondharangalla , Dan Moldovan , Raja Ayyanar

The power generation with non-renewable energy sources has very harmful effects on the environment as well as these sources are depleting. On the other side the renewable energy sources are quite unpredictable source of power. The best…

Systems and Control · Computer Science 2017-01-30 Naresh Kumari , A. N. Jha , Nitin Malik

The current paper presents a Sliding Mode Controller (SMC) for indirect field-oriented Cascaded Doubly Fed Induction Generator (CDFIG) powered through a Matrix Converter (MC). The proposed SMC employs a continuous control strategy to…

Systems and Control · Electrical Eng. & Systems 2022-08-25 A. Maafa , H. Mellah , K. Ghedamsi , D. Aouzellag

Modular Multilevel Converter-based High Voltage Direct Current (MMC-HVDC) system is a promising technology for integration of offshore wind farms (OWFs). However, onshore AC faults on MMC-HVDC reduce the power transfer capability of onshore…

Systems and Control · Electrical Eng. & Systems 2025-11-25 Dileep Kumar , Wajiha Shireen

Wind energy conversion system (WECS) is stochastic in nature and has low inertia to grid voltage instability, poor reactive power compensation and most importantly fault susceptibility. Variable speed WECS such as a doubly-fed induction…

Optimization and Control · Mathematics 2024-07-08 Ayobami Olajube , Satish Vedula , Koto Omiloli , Olugbenga Anubi

Voltage regulation in distribution networks is challenged by increasing penetration of distributed energy resources (DERs). Thanks to advancement in power electronics, these DERs can be leveraged to regulate the grid voltage by quickly…

Optimization and Control · Mathematics 2017-07-25 Hao Jan Liu , Wei Shi , Hao Zhu

This paper proposes a black-start method for an off-grid wind-to-hydrogen (W2H) system comprising a wind farm based on Doubly-Fed Induction Generators (DFIGs), proton exchange membrane fuel cells (PEMFCs) serving as the black-start power…

Systems and Control · Electrical Eng. & Systems 2025-12-19 Bosen Yang , Kang Ma , Jin Lin , Yonghua Song

During grid faults, grid-forming converters are typically suggested to switch from a voltage-source to a current-source mode to limit the current and protect the electronics. This transition has the potential for the converter to…

Systems and Control · Electrical Eng. & Systems 2025-06-25 Youcefa Brahim Elkhalil , Nima Tashakor , Davood Keshavarzi , Ehsan Asadi , Stefan Goetz

With the fast-increasing penetration of inverter-based resources (IBRs), the voltage support capability of the grid following (GFL) IBRs under low voltage ride through (LVRT) control significantly influences the transient voltage stability…

Systems and Control · Electrical Eng. & Systems 2025-09-03 Fangyuan Sun , Ruisheng Diao , Ruiyuan Zeng , Jing Zhang , Jianguo Qian

This paper proposes a novel integrated multiport bidirectional dc-dc converter to interface the battery, the ultra-capacitor, the fuel cell, or other energy sources with the dc-link capacitor of the hybrid energy systems such as the hybrid…

Systems and Control · Electrical Eng. & Systems 2022-09-14 Bang Le-Huy Nguyen , Honnyong Cha , Tuyen Vu , Thai-Thanh Nguyen

In this article, we propose a nonlinear voltage control to ensure power exchange in a multiport interconnected system, which consists of a bidirectional DC-DC converter and generating-storing devices. The converter topology under…

Systems and Control · Electrical Eng. & Systems 2024-04-01 Felipe Morales , Rafael Cisneros , Romeo Ortega , Antonio Sanchez-Squella