Related papers: LORAKI: Autocalibrated Recurrent Neural Networks f…
Purpose: To evaluate an iterative learning approach for enhanced performance of Robust Artificial-neural-networks for K-space Interpolation (RAKI), when only a limited amount of training data (auto-calibration signals, ACS) are available…
Deep learning has been successfully demonstrated in MRI reconstruction of accelerated acquisitions. However, its dependence on representative training data limits the application across different contrasts, anatomies, or image sizes. To…
This study aims to accelerate coronary MRI using a novel reconstruction algorithm, called self-consistent robust artificial-neural-networks for k-space interpolation (sRAKI). sRAKI performs iterative parallel imaging reconstruction by…
Purpose: To develop a scan-specific model that estimates and corrects k-space errors made when reconstructing accelerated Magnetic Resonance Imaging (MRI) data. Methods: Scan-Specific Artifact Reduction in k-space (SPARK) trains a…
Purpose: The goal of this work is to extend the capabilities of RAKI, a k-space interpolating neural network, to reconstruct high-quality images from in-plane accelerated simultaneous multislice imaging acquisitions. This method is referred…
Fast data acquisition in Magnetic Resonance Imaging (MRI) is vastly in demand and scan time directly depends on the number of acquired k-space samples. Recently, the deep learning-based MRI reconstruction techniques were suggested to…
RAKI can perform database-free MRI reconstruction by training models using only auto-calibration signal (ACS) from each specific scan. As it trains a separate model for each individual coil, learning and inference with RAKI can be…
In fMRI, capturing brain activation during a task is dependent on how quickly k-space arrays are obtained. Acquiring full k-space arrays, which are reconstructed into images using the inverse Fourier transform (IFT), that make up volume…
Purpose: Interpretability is essential for the clinical adoption of state-of-the-art machine learning (ML) methods in magnetic resonance imaging (MRI). Conventional evaluation of ML reconstructions relies heavily on aggregate image metrics…
Purpose: Noise resilience in image reconstructions by scan-specific robust artificial neural networks for k-space interpolation (RAKI) is linked to nonlinear activations in k-space. To gain a deeper understanding of this relationship, an…
Parallel imaging is widely used in magnetic resonance imaging as an acceleration technology. Traditional linear reconstruction methods in parallel imaging often suffer from noise amplification. Recently, a non-linear robust…
Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different…
Magnetic resonance imaging (MRI) is one of the noninvasive imaging modalities that can produce high-quality images. However, the scan procedure is relatively slow, which causes patient discomfort and motion artifacts in images. Accelerating…
Deep learning in k-space has demonstrated great potential for image reconstruction from undersampled k-space data in fast magnetic resonance imaging (MRI). However, existing deep learning-based image reconstruction methods typically apply…
Cardiac Cine Magnetic Resonance Imaging (MRI) provides an accurate assessment of heart morphology and function in clinical practice. However, MRI requires long acquisition times, with recent deep learning-based methods showing great promise…
Image reconstruction from undersampled k-space data plays an important role in accelerating the acquisition of MR data, and a lot of deep learning-based methods have been exploited recently. Despite the achieved inspiring results, the…
Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and…
Acquiring fully-sampled MRI $k$-space data is time-consuming, and collecting accelerated data can reduce the acquisition time. Employing 2D Cartesian-rectilinear subsampling schemes is a conventional approach for accelerated acquisitions;…
k-space undersampling is a standard technique to accelerate MR image acquisitions. Reconstruction techniques including GeneRalized Autocalibrating Partial Parallel Acquisition(GRAPPA) and its variants are utilized extensively in clinical…
Recent medical image reconstruction techniques focus on generating high-quality medical images suitable for clinical use at the lowest possible cost and with the fewest possible adverse effects on patients. Recent works have shown…