English
Related papers

Related papers: Two-Colour Interferometry and Thomson Scattering M…

200 papers

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1…

We present the first two-dimensional (2D) optical Thomson scattering measurements of electron density and temperature in laser-produced plasmas. The novel instrument directly measures $n_e(x,y)$ and $T_e(x,y)$ in two dimensions over large…

Instrumentation and Detectors · Physics 2023-09-12 H. Zhang , J. J. Pilgram , C. G. Constantin , L. Rovige , P. V. Heuer , S. Ghazaryan , M. Kaloyan , R. S. Dorst , D. B. Schaeffer , C. Niemann

Collective X-ray Thomson scattering has become a versatile tool for the diagnostics of dense plasmas. Assuming homogeneous density and temperature throughout the target sample, these parameters can be determined directly from the plasmon…

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint…

We propose a collective Thomson scattering experiment at the VUV free electron laser facility at DESY (FLASH) which aims to diagnose warm dense matter at near-solid density. The plasma region of interest marks the transition from an ideal…

Plasma Physics · Physics 2015-06-26 A. Hoell

Incoherent Thomson scattering is a non-intrusive technique commonly used for measuring local plasma density. Within low-density, low-temperature plasma's and for sufficient laser intensity, the laser may perturb the local electron density…

Plasma Physics · Physics 2018-05-29 Andrew T. Powis , Mikhail N. Shneider

This work proposes a novel method of Thomson microwave scattering for electron number density measurements of miniature plasmas at pressures < 10 Torr. This method is applied to determine electron number density in a positive column of glow…

Plasma Physics · Physics 2019-05-20 Xingxing Wang , Apoorv Ranjan , Animesh Sharma , Mikhail N. Shneider , Alexey Shashurin

Non-classical electron diffusion in crossed-field, low-temperature plasmas is measured experimentally. Laser-induced fluorescence and Thomson scattering are used to determine the inverse Hall parameter, a metric for cross-field transport,…

Plasma Physics · Physics 2024-04-01 Parker J. Roberts , Benjamin A. Jorns

A self-consistent kinetic theory of Thomson scattering of an electromagnetic field by a non-uniform plasma is derived. We draw the readers' attention to the inconsistency in recent results on the Thomson scattering in inhomogeneous plasma,…

Plasma Physics · Physics 2018-05-16 V. V. Belyi

X-ray Thomson scattering is being developed as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. Most experiments are currently done…

Plasma Physics · Physics 2015-06-17 J. Nilsen , W. R. Johnson , K. T. Cheng

We discuss the conceptual design of a spatially-resolved spectroscopy system of Thomson scattering with high wavelength resolution capable of measuring the shape of electron velocity distribution functions in magnetically confined plasmas.…

We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure…

In inertial confinement fusion (ICF), Thomson scattering (TS) is a widely used diagnostic technique for probing plasma conditions. We present a first-principles numerical approach to obtaining scattered light signals of ion acoustic…

The traditional Thomson scattering diagnostic is based on measurement of the wavelength spectrum of scattered light, where electron temperature measurements are inferred from thermal broadening of the scattered laser light. At sufficiently…

Plasma Physics · Physics 2015-06-17 E. Parke , V. V. Mirnov , D. J. Den Hartog

We present a space and time resolved interferometric plasma diagnostic for use on plasmas where neutral-bound electron contribution to the refractive index cannot be neglected. By recording simultaneously the plasma optical index at 532 and…

X-ray Thomson scattering is being developed as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such as those used in inertial confinement fusion. X-ray laser sources have always…

Plasma Physics · Physics 2015-06-12 J. Nilsen , W. R. Johnson , K. T. Cheng

Thomson scattering of laser light is one of the most fundamental diagnostics of plasma density, temperature and magnetic fields. It relies on the assumption that the properties in the probed volume are homogeneous and constant during the…

Plasma Physics · Physics 2016-04-29 P. M. Kozlowski , B. J. B. Crowley , D. O. Gericke , S. P. Regan , G. Gregori

Thomson scattering in non-ideal (collision-dominated) two-component plasmas is calculated accounting for electron-ion collisions as well as electron-electron correlations. This is achieved by using a novel interpolation scheme for the…

Plasma Physics · Physics 2013-05-29 Carsten Fortmann , August Wierling , Gerd Röpke

For the last decade numerous researchers have been trying to develop experimental techniques to use X-ray Thomson scattering as a method to measure the temperature, electron density, and ionization state of high energy density plasmas such…

Plasma Physics · Physics 2012-10-02 J. Nilsen , W. R. Johnson , K. T. Cheng

The paper is devoted to the Thomson scattering (TS) diagnostics recently developed for the Globus-M2 spherical tokamak and prototyping the ITER divertor TS diagnostics. The distinctive features of the system are the use of spectrometers,…

‹ Prev 1 2 3 10 Next ›