English
Related papers

Related papers: Design and Analysis of Microfluidic Cell Counter u…

200 papers

Cells, other than their biological properties, have different electric and physical properties. In an impedance cytometer, cells should pass one by one in the detection region where pairs of electrodes are located. When cells are located…

Signal Processing · Electrical Eng. & Systems 2022-03-09 Hassan Raji , Iraj Dehghan Hamani

An analytical formula for electrical impedance between an adherent living cell and sensor substrate measured using a microelectrode is presented for the first time. Previously-reported formula has been applicable only for the case where…

Biological Physics · Physics 2022-11-11 Masataka Shiozawa , Shigeyasu Uno

We have developed and characterized two novel micro flow sensors based on measuring the electrical impedance of the interface between the flowing liquid and metallic electrodes embedded on the channel walls. These flow sensors are very…

Fluid Dynamics · Physics 2012-07-17 Nima Arjmandi , Chengxun Liu , Willem Van Roy , Liesbet Lagae , Gustaaf Borghs

Microfluidic fuel cells (MFCs) are microfluidic electrochemical conversion devices that are used to power small pieces of electrical equipment. Their performance relies on the improvement of the mass transfer of the reactants at the…

The mechanical properties of PC12 living cells have been studied at the nanoscale with a Force Feedback Microscope using two experimental approaches. Firstly, the local mechanical impedance of the cell membrane has been mapped…

We outline calibrated measurements of the microwave reflection coefficient from the tunnel junction of an ultra-high vacuum low temperature scanning tunneling microscope. The microwave circuit design is described in detail, including an…

Instrumentation and Detectors · Physics 2023-09-14 Bareld Wit , Georg Gramse , Stefan Müllegger

Bacteria sense a diverse range of environmental analytes with high sensitivity and temporal resolution. Engineering and synthetic biology approaches enabled harnessing this capability through development of whole-cell biosensors that…

Cellular metabolic rate is a good indicator of the physiological state of cells and its changes, which can be measured by total heat flux accompanying metabolism. Chip calorimeters can provide label-free and high throughput measurements of…

Biological Physics · Physics 2019-03-13 Jihye Kim , Sumin Seo , Jonghyun Kim , Sungmin Nam , Wonhee Lee

Micromanipulations, perfusions and measurements performed using glass microelectrodes filled with an electrolyte is a conventional technique for experimental morphological and membrane electrophysiological studies at a single cell and…

Subcellular Processes · Quantitative Biology 2018-07-27 O. V. Gradov , P. A. Nasirov , A. A. Scrynnic , A. G. Jablokov

Microwave sensors integrated with microfluidic platforms can provide the size and permittivity of single cells and microparticles. Amongst the microwave sensor topologies, the planar arrangement of electrodes is a popular choice owing to…

Portable low-cost sensors and sensing systems for the identification and quantitative measurement of bacteria in field water are critical in preventing drinking water from being contaminated by bacteria. In this article, we reported the…

Quantitative Methods · Quantitative Biology 2013-12-03 Jing Jiang , Xinhao Wang , Ran Chao , Yukun Ren , Chengpeng Hu , Zhida Xu , Gang Logan Liu

Optical methods for monitoring the electrochemical reaction at the interface are advantageous because of their table-top setup and ease of integration into reactors. Here we apply EDL-modulation microscopy to one of the main components of…

Chemical Physics · Physics 2023-03-21 Zhu Zhang , Sanli Faez

Selectivity and sensitivity are important figures of merit in the design and optimization of electrochemical biosensors. The efficiency of the fabricated immunosensing surface can easily be influenced by several factors, such as detection…

Accurate and integrable control of different flows within microfluidic channels is crucial to further development of lab-on-a-chip and fully integrated adaptable structures. Here we introduce a flexible microactuator that buckles at a high…

Fluid Dynamics · Physics 2016-04-20 Behrouz Tavakol , Douglas P. Holmes

Encapsulation of chemicals using polymer membranes enables to control their transport and delivery for applications such as agrochemistry or detergency. To rationalize the design of polymer capsules, it is necessary to understand how the…

Soft Condensed Matter · Physics 2018-12-18 Corentin Tregouët , Thomas Salez , Mathilde Reyssat , Cécile Monteux

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Studies of biological solutions require high measurement accuracy, the ability to detect low changes in substance concentration, and small amounts of the liquid under test. A microwave complex permittivity measurement technique based on a…

Microplastics are increasingly recognized as a global environmental health threat, yet their detection and characterization remain constrained by the cost, form factor, and throughput of existing analytical tools. Portable…

Applied Physics · Physics 2025-10-31 Sayedus Salehin , Syed Shaheer Uddin Ahmed , Uzay Tefek , Laura Weirauch , M. Selim Hanay

A research of inductive conductometric cell is presented. An equivalent circuit and a mathematical model of inductive cell are given in the article. The model takes into account sample-coil capacity (i.e. capacity formed by the coil and the…

Instrumentation and Detectors · Physics 2013-05-01 Yury S. Semenov

Rapid identification of microparticles in liquid is an important problem in environmental and biomedical applications such as for microplastic detection in water sources and physiological fluids. Existing spectro-scopic techniques are…

Applied Physics · Physics 2024-11-20 Yagmur Ceren Alatas , Uzay Tefek , Sayedus Salehin , Hashim Alhmoud , M. Selim Hanay
‹ Prev 1 2 3 10 Next ›