English
Related papers

Related papers: Time resolution studies for scintillating plastics…

200 papers

The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…

Instrumentation and Detectors · Physics 2022-09-21 Marco Alberto Ayala-Torres , Luis Manuel Montaño Zetina , Marcos Fontaine Sánchez

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

Instrumentation and Detectors · Physics 2014-10-17 Paolo W. Cattaneo , Matteo De Gerone , Flavio Gatti , Miki Nishimura , Wataru Ootani , Massimo Rossella , Yusuke Uchiyama

The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

Instrumentation and Detectors · Physics 2021-09-08 Alexey Stoykov , Tigran Rostomyan

A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…

Instrumentation and Detectors · Physics 2024-08-19 N. Karpushkin , D. Finogeev , F. Guber , D. Lyapin , A. Makhnev , S. Morozov , D. Serebryakov

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

Instrumentation and Detectors · Physics 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…

Instrumentation and Detectors · Physics 2019-08-13 Christian Soldner

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…

In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…

Instrumentation and Detectors · Physics 2015-05-28 A. Stoykov , R. Scheuermann , K. Sedlak

We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence…

Instrumentation and Detectors · Physics 2015-10-26 L. Gruber , S. E. Brunner , C. Curceanu , J. Marton , A. Romero Vidal , A. Scordo , K. Suzuki , O. Vazquez Doce

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

Instrumentation and Detectors · Physics 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…

Instrumentation and Detectors · Physics 2017-01-04 S. Cecchini , I. D'Antone , L. Degli Esposti , I. Lax , G. Mandrioli , N. Mauri , L. Pasqualini , L. Patrizii , M. Pozzato , G. Sirri , M. Tenti

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area…

Instrumentation and Detectors · Physics 2011-09-23 Gama Ahmed , Paul Bühler , Johann Marton , Ken Suzuki

The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A…

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a…

We report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5 cm diameter x 5 cm thick and 7 cm diameter x 7 cm thick {\it trans}-stilbene crystals read out with the passively summed output of three different…

Instrumentation and Detectors · Physics 2020-01-08 Melinda Sweany , Peter Marleau , Chris Allwork , Gene Kallenbach , Steven Hammon

This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times…

Instrumentation and Detectors · Physics 2020-10-12 G. Boca , P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nakao , M. Nishimura , W. Ootani , M. Rossella , Y. Uchiyama , M. Usami , K. Yanai