Related papers: Adversarial Sparse-View CBCT Artifact Reduction
Recent CT Metal Artifacts Reduction (MAR) methods are often based on image-to-image convolutional neural networks for adjustment of corrupted sinograms or images themselves. In this paper, we are exploring the capabilities of a multi-domain…
X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the…
Sparse-view computed tomography (CT) -- using a small number of projections for tomographic reconstruction -- enables much lower radiation dose to patients and accelerated data acquisition. The reconstructed images, however, suffer from…
Most of the adversarial attack methods suffer from large perceptual distortions such as visible artifacts, when the attack strength is relatively high. These perceptual distortions contain a certain portion which contributes less to the…
Nona-Bayer colour filter array (CFA) pattern is considered one of the most viable alternatives to traditional Bayer patterns. Despite the substantial advantages, such non-Bayer CFA patterns are susceptible to produce visual artefacts while…
Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current…
Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods which rely heavily on synthesized data for training. However, as synthesized data may not perfectly simulate the…
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray…
Reconstructing 3D cone beam computed tomography (CBCT) images from a limited set of projections is an important inverse problem in many imaging applications from medicine to inertial confinement fusion (ICF). The performance of traditional…
X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP)…
X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…
X-ray computed tomography (CT) is widely used in medical imaging, with sparse-view reconstruction offering an effective way to reduce radiation dose. However, ill-posed conditions often result in severe streak artifacts. Recent advances in…
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…
Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…
Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed…
The existence of metallic implants in projection images for cone-beam computed tomography (CBCT) introduces undesired artifacts which degrade the quality of reconstructed images. In order to reduce metal artifacts, projection inpainting is…
Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low…
Limited-view computed tomography (CT) presents significant potential for reducing radiation exposure and expediting the scanning process. While deep learning (DL) methods have exhibited promising results in mitigating streaking artifacts…
Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter…
A major challenge in X-ray computed tomography (CT) is reducing radiation dose while maintaining high quality of reconstructed images. To reduce the radiation dose, one can reduce the number of projection views (sparse-view CT); however, it…