English
Related papers

Related papers: Expected performance of the TT-PET scanner

200 papers

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…

Instrumentation and Detectors · Physics 2015-06-11 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…

Instrumentation and Detectors · Physics 2021-03-02 Carmen Romo-Luque

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…

Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…

Instrumentation and Detectors · Physics 2026-03-30 B. Li , Y. Ma , K. Ni

Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive…

Instrumentation and Detectors · Physics 2007-05-23 A. Fedorov , A. Annenkov , A. Kholmetsky , M. Korzhik , P. Lecoq , A. Lobko , O. Missevitch , A. Tkatchov

Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…

Robotics · Computer Science 2023-12-01 Junxiang Wang , Ti Wu , Iulian I. Iordachita , Peter Kazanzides

Images recorded below the surface of a finger can have more details and be of higher quality than the conventional surface fingerprint images. This is particularly true when the quality of the surface fingerprints is compromised by, for…

Medical Physics · Physics 2017-09-13 Egidijus Auksorius , A. Claude Boccara

PETALO (Positron Emission Tof Apparatus with Liquid xenOn) is a novel concept for positron emission tomography scanners, which uses liquid xenon as a scintillation medium and silicon photomultipliers as a readout. The large scintillation…

Instrumentation and Detectors · Physics 2022-02-02 Paola Ferrario

Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly uesd for studying the animal model of disease, new drugs and new therapies. A prototype of…

Instrumentation and Detectors · Physics 2019-09-26 Peipei Deng , Lei Zhao , Jiaming Lu , Bowen Li , Ruoshi Dong , Shubin Liu , Qi An

The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…

Medical Physics · Physics 2008-05-06 N. D'Ascenzo , E. Garutti , M. Goettlich , H. C. Schultz-Coulon , A. Tadday

We present a rapid-scan, time-domain terahertz spectrometer employing femtosecond Er:fiber technology and an acousto-optic delay with attosecond precision, enabling scanning of terahertz transients over a 12.4 ps time window at a waveform…

Optics · Physics 2016-04-14 B. Urbanek , M. Möller , M. Eisele , S. Baierl , D. Kaplan , C. Lange , R. Huber

GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of…

Medical Physics · Physics 2015-06-26 S. Jan , J. Collot , M. -L. Gallin-Martel , P. Martin , F. Mayet , E. Tournefier

In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…

Instrumentation and Detectors · Physics 2020-02-13 S. Salvador , E. Barlerin , J. Perronnel , C. Vandamme

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

Instrumentation and Detectors · Physics 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high…

Instrumentation and Detectors · Physics 2014-09-22 Qiang Wang , Aswin J. Mathews , Ke Li , Jie Wen , Sergey Komarov , Joseph A. O'Sullivan , Yuan-Chuan Tai

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking…

‹ Prev 1 3 4 5 6 7 10 Next ›