English
Related papers

Related papers: Method of EAS's Cherenkov and fluorescent light se…

200 papers

The detection of Cerenkov light from EAS in a delayed coincidence with fluorescence light gives a strong signature to discriminate protons and neutrinos in cosmic rays. For this purpose, the ULTRA experiment has been designed with 2…

An established technique for the measurement of ultra-high-energy-cosmic-rays is the detection of the fluorescence light induced in the atmosphere of the Earth, by means of telescopes equipped with photomultiplier tubes. Silicon…

Silicon photomultipliers are increasingly replacing photomultiplier tubes in Cherenkov telescope cameras, but achieving single-photoelectron resolution with nanosecond timing in a low-noise, scalable detector system remains challenging. We…

Instrumentation and Methods for Astrophysics · Physics 2026-05-12 Luca Giangrande , Matthieu Heller , Teresa Montaruli

The operation of a small-size Cherenkov gamma-ray telescope TAIGA-IACT with camera on SiPMs OnSemi MicroFJ-60035 has been modelled by multiparticle Monte Carlo (MC) methods. The model implies that telescope camera is equipped with two…

The timing and spectral characteristics of four highly efficient, slow fluors are presented for liquid scintillator solutions using linear alkylbenzene (LAB) as the primary solvent. The mixtures exhibit high light yields, but with rise…

Instrumentation and Detectors · Physics 2020-05-26 Steven D. Biller , Edward J. Leming , Josephine L. Paton

The detailed simulation of extended air showers (EAS) and their emission of Cherenkov and fluorescence light requires increasing computation time and storage volume with increasing energy of the primary particle. Given these limitations, it…

Instrumentation and Methods for Astrophysics · Physics 2023-07-28 Ali Baktash , Dieter Horns

A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research…

Instrumentation and Detectors · Physics 2010-03-04 S. Korpar , I. Adachi , H. Chagani , R. Dolenec , K. Hara , T. Iijima , P. Krizan , S. Nishida , R. Pestotnik , A. Stanovnik

Gamma-ray observations in the very-high-energy domain (E > 30 GeV) can exploit the imaging of few-nanosecond Cherenkov flashes from atmospheric particle showers. Photomultipliers have been used as the primary photosensors to detect…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Jonathan Biteau , David Chinn , Dennis Dang , Kevin Doyle , Caitlin A. Johnson , David A. Williams

The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50-300 TeV, where…

Instrumentation and Methods for Astrophysics · Physics 2023-09-19 Akira Okumura , Kawori Wakazono , Kazuhiro Furuta , Hiroyasu Tajima

Silicon photomultipliers (SiPMs) have a few advantages over conventional photomultiplier tubes (PMTs) used in imaging atmospheric Cherenkov telescopes. The first notable characteristic is their higher photon detection efficiency (PDE) of up…

Instrumentation and Methods for Astrophysics · Physics 2023-09-19 Akira Okumura , Junya Haga , Chiaki Inoue , Keiji Nishimoto , Kazuhiro Furuta , Hiroyasu Tajima

The demand for novel detector mediums such as Water-based Liquid Scintillator (WbLS) has increased over the last few decades due to their capability for both low energy particle interactions and higher light yield. Recently, the usage of…

High Energy Physics - Experiment · Physics 2024-06-14 Emrah Tiras , Merve Tas , Dilara Kizilkaya , Muhammet Anil Yagiz , Mustafa Kandemir

A new method for energy and mass composition estimation of primary cosmic ray radiation based on atmospheric Cerenkov light flux in extensive air showers (EAS) analysis is proposed. The Cerenkov light flux in EAS initiated by primary…

Astrophysics · Physics 2009-11-10 S. Mavrodiev , A. Mishev , J. Stamenov

We report on the separation of Cherenkov and scintillation light in BGO and BSO crystals read out with silicon photomultipliers (SiPMs). The two light components are disentangled on an event-by-event basis by combining optical filtering…

Recent developments in photo-detectors and photo-detector systems are reviewed. The main emphasis is made on Silicon Photo-Multipliers (SiPM) - novel and very attractive photo-detectors. Their main features are described. Properties of…

Instrumentation and Detectors · Physics 2009-06-23 M. Danilov

In this paper, we describe the first tests of a dual-readout fiber calorimeter in which silicon photomultipliers are used to sense the (scintillation and Cherenkov) light signals. The main challenge in this detector is implementing a design…

The development of detectors using Silicon Photo-Multipliers for acquisition of fast light signals coming from Cherenkov and fluorescence emissions started by particle showers in the terrestrial atmosphere is the main goal of the Italian…

Instrumentation and Methods for Astrophysics · Physics 2026-01-19 Rossella Caruso

A Cherenkov detector based on an array of five lead fluoride ($\beta$-PbF$_2$) crystals of size 30 mm$\times$30 mm$\times$160 mm read out by reverse-type avalanche photodiodes (APD's) of active area 10 mm$\times$10 mm was used to measure…

Instrumentation and Detectors · Physics 2019-11-07 Y. Murakami , H. Aghai-Khozani , M. Hori

The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady…

Instrumentation and Methods for Astrophysics · Physics 2024-04-23 A. Hahn , R. Mirzoyan , A. Dettlaff , D. Fink , D. Mazin , M. Teshima

The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two…

Instrumentation and Detectors · Physics 2019-08-14 G. Ambrosi , F. Acerbi , E. Bissaldi , A. Ferri , F. Giordano , A. Gola , M. Ionica , R. Paoletti , C. Piemonte , G. Paternoster , D. Simone , V. Vagelli , G. Zappala , N. Zorzi
‹ Prev 1 2 3 10 Next ›