English
Related papers

Related papers: Resolution Guarantees in Electrical Impedance Tomo…

200 papers

We propose a way to measure the qubit state of an arbitrary sub-ensemble of atoms in an array without significantly disturbing the quantum information in the unmeasured atoms. The idea is to first site-selectively transfer atoms out of the…

Quantum Physics · Physics 2022-05-04 Felipe Giraldo Mejia , Aishwarya Kumar , Tsung-Yao Wu , Peng Du , David S. Weiss

Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows a continuous assessment of changes in regional bioimpedance of different organs. One of its most common biomedical applications is monitoring regional…

Image and Video Processing · Electrical Eng. & Systems 2020-10-20 Nils Strodthoff , Claas Strodthoff , Tobias Becher , Norbert Weiler , Inéz Frerichs

In Electrical Impedance Tomography (EIT) one wants to image the conductivity distribution of a body from current and voltage measurements carried out on its boundary. In this paper we consider the underlying mathematical model, the inverse…

Numerical Analysis · Mathematics 2017-04-10 Andreas Hauptmann , Matteo Santacesaria , Samuli Siltanen

This document reports an Open 2D Electrical Impedance Tomography (EIT) data set. The EIT measurements were collected from a circular body (a flat tank filled with saline) with various choices of conductive and resistive inclusions. Data are…

Which systems are ideal to obtain negative refraction with no absorption? Electromagnetically induced transparency (EIT) is a method to suppress absorption and make a material transparent to a field of a given frequency. Such a system has…

Optics · Physics 2012-10-31 R. M. Rajapakse , E. Kuznetsova , S. F. Yelin

In computational PDE-based inverse problems, a finite amount of data is collected to infer unknown parameters in the PDE. In order to obtain accurate inferences, the collected data must be informative about the unknown parameters. How to…

Numerical Analysis · Mathematics 2021-05-04 Tan Bui-Thanh , Qin Li , Leonardo Zepeda-Núñez

For the linearized reconstruction problem in Electrical Impedance Tomography (EIT) with the Complete Electrode Model (CEM), Lechleiter and Rieder (2008 Inverse Problems 24 065009) have shown that a piecewise polynomial conductivity on a…

Analysis of PDEs · Mathematics 2019-01-04 Bastian Harrach

Electrical impedance tomography aims at reconstructing the interior electrical conductivity from surface measurements of currents and voltages. As the current-voltage pairs depend nonlinearly on the conductivity, impedance tomography leads…

Numerical Analysis · Mathematics 2017-05-31 Nuutti Hyvönen , Lauri Mustonen

Electrical Impedance Tomography (EIT) is a non-invasive, low-cost bedside imaging modality with high temporal resolution, making it suitable for bedside monitoring. However, its inherently ill-posed inverse problem poses significant…

Computer Vision and Pattern Recognition · Computer Science 2025-07-21 Hao Fang , Sihao Teng , Hao Yu , Siyi Yuan , Huaiwu He , Zhe Liu , Yunjie Yang

The aim of electrical impedance tomography is to reconstruct the admittivity distribution inside a physical body from boundary measurements of current and voltage. Due to the severe ill-posedness of the underlying inverse problem, the…

Analysis of PDEs · Mathematics 2022-07-19 Jérémi Dardé , Nuutti Hyvönen , Aku Seppänen , Stratos Staboulis

We develop a boundary integral equation-based numerical method to solve for the electrostatic potential in two dimensions, inside a medium with piecewise constant conductivity, where the boundary condition is given by the complete electrode…

Numerical Analysis · Mathematics 2024-03-28 Teemu Tyni , Adam R Stinchcombe , Spyros Alexakis

In acousto-electric tomography the goal is to reconstruct the electric conductivity in a domain from electrostatic boundary measurements of corresponding currents and voltages, while the domain is penetrated by a time-dependent acoustic…

Medical Physics · Physics 2024-02-01 Bjørn Jensen , Adrian Kirkeby , Kim Knudsen

A test of Lorentz invariance has been performed using an EIT resonance as a precision frequency discriminator within an Ives-Stilwell like apparatus. We analyse the experiment within the framework of the Standard Model Extension and have…

Atomic Physics · Physics 2007-05-23 J. P. Cotter , B. Varcoe

The regularized D-bar method is a popular method for solving Electrical Impedance Tomography (EIT) problems due to its efficiency and simplicity. It utilizes the low-pass truncated scattering data in the non-linear Fourier domain to solve…

Numerical Analysis · Mathematics 2025-02-10 Xiang Cao , Qiaoqiao Ding , Xiaoqun Zhang

Acousto-electric tomography (AET) is a hybrid imaging modality that combines electrical impedance tomography with focused ultrasound perturbations to obtain interior power density measurements, which provide additional information that can…

Analysis of PDEs · Mathematics 2026-03-31 Hjørdis Schlüter , Babak Maboudi Afkham

Electrical Impedance Tomography (EIT) is a non-invasive medical imaging method that reconstructs electrical conductivity mediums from boundary voltage-current measurements, but its severe ill-posedness renders direct operator learning with…

Numerical Analysis · Mathematics 2026-01-14 Amit Bhat , Ke Chen , Chunmei Wang

Electrical impedance tomography (EIT) is a non-invasive functional imaging technology. In order to enhance the quality of lung EIT images, novel algorithms, namely LSTM-LSTM, LSTM-BiLSTM, BiLSTM-LSTM, and BiLSTM-BiLSTM, leveraging LSTM or…

Biological Physics · Physics 2025-04-22 Zhenzhong Song , Jianping Li , Jun Zhang , Hanyun Wen , Suqin Zhang , Wei Jiang , Xingxing Zhou

Electromagnetically induced transparency (EIT) is a phenomenon that can provide strong and robust interfacing between optical signals and quantum coherence of electronic spins. In its archetypical form, mainly explored with atomic media, it…

We propose a method based on the Electromagnetically Induced Transparency (EIT) phenomenon for the detection of molecules which exist as a small minority in the presence of a majority of absorbers. The EIT effect we employ effectively…

Quantum Physics · Physics 2012-01-04 Asaf Eliam , Evgeny A. Shapiro , Moshe Shapiro

Studies of models of current flow behaviour in Electrical Impedance Tomography (EIT) have shown that the current density distribution varies extremely rapidly near the edge of the electrodes used in the technique. This behaviour imposes…

High Energy Physics - Theory · Physics 2009-10-30 S. Ciulli , S. Ispas , M. K. Pidcock