English
Related papers

Related papers: A compact, high resolution tracker for cosmic ray …

200 papers

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

The detection of photons produced during the avalanche development in gas chambers has been the subject of detailed studies in the past. The great progresses achieved in last years in the performance of micro-pattern gas detectors on one…

Instrumentation and Detectors · Physics 2016-01-20 Michela Marafini , Vincenzo Patera , Davide Pinci , Alessio Sarti , A. Sciubba , Eleuterio Spiriti

Muon imaging, especially muon scattering tomography (MST), has recently garnered significant attention. MST measures the magnitude of muon scattering angles inside an object, which depends not only on the material properties but also on the…

Instrumentation and Detectors · Physics 2025-09-17 Pei Yu , Ziwen Pan , Jiajia Zhai , Yu Xu , Li Deng , Zhengyang He , Zhe Chen , Zechao Kang , Yuhong Yu , Xueheng Zhang , Liangwen Chen , Lei Yang , Zhiyu Sun

Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…

High Energy Physics - Experiment · Physics 2026-05-07 Yan Niu , Anqing Wang , Xiangxiang Ren , Dong Liu , Meng Wang

We have re-purposed portable plastic scintillator muon detectors, designed by the CosmicWatch project, for the measurement of electrons emitted by the decay of radioactive sources. For the latter purpose we have first calibrated the…

Instrumentation and Detectors · Physics 2019-08-20 Joaquin Masias , Franco Delgado , Lucía Coll , Alicia Pérez , José Bazo , Alberto Gago

This paper describes a new measurement of the flux ratio of positive and negative muons from cosmic-ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The…

High Energy Physics - Experiment · Physics 2010-10-07 Gavin Hesketh

We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion collider. We utilize Multi-gap Resistive…

A high-statistics determination of the differential cross section of elastic muon-electron scattering as a function of the transferred four-momentum squared, $d \sigma_{el}(\mu e \to \mu e)/dq^2$, has been argued to provide an effective…

Instrumentation and Detectors · Physics 2020-02-25 Tommaso Dorigo

A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or…

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory at Madurai for measuring its efficiency at shallow…

The radiation hardness of passive CMOS pixel sensors fabricated in 150 nm LFoundry technology is investigated. CMOS process lines are especially of interest for large-scale silicon detectors as they offer high production throughput at…

Muon tomography is a technique that uses cosmic ray muons to generate three dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to…

Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the…

For many years there has been an aspiration within the community to develop curved silicon detectors for particle physics applications. We present the results from 10 x 10cm low mass support modules as a part of the "ZeroMass" project that…

Instrumentation and Detectors · Physics 2025-03-07 Sam Moss , Zhidong Zhang , Adrian Bevan , Mark Bullough , Jens Dopke , Jag Mistry , Seth Zenz

We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…

Instrumentation and Detectors · Physics 2007-05-23 T. Hotta , M. Fujiwara , T. Kinashi , Y. Kuno , M. Kuss , T. Matsumura , T. Nakano , S. Sekikawa , H. Tajima

We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very…

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for $0.2 < p_T < 2$ GeV/c in the…

Instrumentation and Detectors · Physics 2025-01-16 J. D. Brandenburg , Y. Chang , J. Dong , Y. He , Y. Hu , B. Huang , H. Huang , T. Huang , H. Li , M. Nie , R. Sharma , X. Sun , P. Tribedy , F. Videbæk , G. Visser , G. Wilks , P. Wang , G. Xie , G. Yan , Z. Ye , L. Yi , Y. Yang , S. Zhang , Z. Zhang

The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance,…

Instrumentation and Detectors · Physics 2016-10-04 B. Bittner , J. Dubbert , O. Kortner , H. Kroha , F. Legger , R. Richter , O. Biebel , A. Engl , R. Hertenberger , F. Rauscher

The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter in charge of the electron background rejection downstream of the cooling channel at the international Muon Ionization Cooling Experiment. It consists of 2832 plastic…

Instrumentation and Detectors · Physics 2017-10-20 Francois Drielsma