English
Related papers

Related papers: Skin optical attenuation coefficient modulation wi…

200 papers

Photoplethysmography (PPG) is a simple and inexpensive technology used in many smart devices to monitor cardiovascular health. The PPG sensors use LED lights to penetrate into the bloodstream to detect the different blood volume changes in…

Medical Physics · Physics 2021-10-22 Irene Pi , Isleen Pi , Wei Wu

Remote photoplethysmography (rPPG) is an innovative method for monitoring heart rate and vital signs by using a simple camera to record a person, as long as any part of their skin is visible. This low-cost, contactless approach helps in…

Computer Vision and Pattern Recognition · Computer Science 2025-10-08 Zahra Maleki , Amirhossein Akbari , Amirhossein Binesh , Babak Khalaj

Remote photoplethysmography (rPPG) allows for noncontact monitoring of blood volume changes from a camera by detecting minor fluctuations in reflected light. Prior applications of rPPG focused on face videos. In this paper we explored the…

Computer Vision and Pattern Recognition · Computer Science 2023-03-23 Lu Niu , Jeremy Speth , Nathan Vance , Benjamin Sporrer , Adam Czajka , Patrick Flynn

Photoplethysmography (PPG) is a method of detecting variation in blood volume commonly through contact with the skin and involving the usage of one or multiple sensors. PPG is typically used in health-related fields and one of its most…

Medical Physics · Physics 2021-08-24 Jiesheng He , Wei Wu

Vital signs such as pulse rate and breathing rate are currently measured using contact probes. But, non-contact methods for measuring vital signs are desirable both in hospital settings (e.g. in NICU) and for ubiquitous in-situ health…

Computer Vision and Pattern Recognition · Computer Science 2015-03-25 Mayank Kumar , Ashok Veeraraghavan , Ashutosh Sabharval

The ability to reliably estimate physiological signals from video is a powerful tool in low-cost, pre-clinical health monitoring. In this work we propose a new approach to remote photoplethysmography (rPPG) - the measurement of blood volume…

Computer Vision and Pattern Recognition · Computer Science 2021-11-19 John Gideon , Simon Stent

Photoplethysmography (PPG) refers to the measurement of variations in blood volume using light and is a feature of most wearable devices. The PPG signals provide insight into the body's circulatory system and can be employed to extract…

Signal Processing · Electrical Eng. & Systems 2024-01-17 Yuyang Miao , Harry J. Davies , Danilo P. Mandic

Photoplethysmography (PPG) is a non-invasive technology that measures changes in blood volume in the microvascular bed of tissue. It is commonly used in medical devices such as pulse oximeters and wrist worn heart rate monitors to monitor…

Remote photoplethysmography (rPPG) enables non-contact measurement of cardiac pulse signals by analyzing subtle color changes in facial videos. Nevertheless, extracting rPPG signals remains challenging because of their extremely weak signal…

Image and Video Processing · Electrical Eng. & Systems 2026-05-22 Kosuke Kurihara , Yoshihiro Maeda , Daisuke Sugimura , Takayuki Hamamoto

Photoplethysmography (PPG) devices are widely used for monitoring cardiovascular function. However, these devices require skin contact, which restrict their use to at-rest short-term monitoring using single-point measurements.…

Biometric authentication prospered because of its convenient use and security. Early generations of biometric mechanisms suffer from spoofing attacks. Recently, unobservable physiological signals (e.g., Electroencephalogram,…

Cryptography and Security · Computer Science 2024-01-29 Lin Li , Chao Chen , Lei Pan , Leo Yu Zhang , Zhifeng Wang , Jun Zhang , Yang Xiang

Photoplethysmographic imaging is a camera-based solution for non-contact cardiovascular monitoring from a distance. This technology enables monitoring in situations where contact-based devices may be problematic or infeasible, such as…

Computer Vision and Pattern Recognition · Computer Science 2016-06-30 Robert Amelard , David A Clausi , Alexander Wong

In the first half of the 20th century, a first pulse oximeter was available to measure blood flow changes in the peripheral vascular net. However, it was not until recent times the PhotoPlethysmoGraphic (PPG) signal used to monitor many…

Signal Processing · Electrical Eng. & Systems 2020-12-21 Javier de Pedro-Carracedo , David Fuentes-Jimenez , Ana M. Ugena , Ana P. Gonzalez-Marcos

Camera-based remote photoplethysmography (rPPG) provides a non-contact way to measure physiological signals (e.g., heart rate) using facial videos. Recent deep learning architectures have improved the accuracy of such physiological…

Computer Vision and Pattern Recognition · Computer Science 2021-06-14 Yunhao Ba , Zhen Wang , Kerim Doruk Karinca , Oyku Deniz Bozkurt , Achuta Kadambi

Remote photoplethysmography (rPPG) enables non-contact heart rate measurement from facial videos, but its performance is significantly degraded by facial motions such as speaking and head shaking. To address this issue, we propose two…

Computer Vision and Pattern Recognition · Computer Science 2026-04-14 Gan Pei , Junhao Ning , Boqiu Shen , Yan Zhu , Menghan Hu

Facial video-based remote physiological measurement aims to estimate remote photoplethysmography (rPPG) signals from human face videos and then measure multiple vital signs (e.g. heart rate, respiration frequency) from rPPG signals. Recent…

Computer Vision and Pattern Recognition · Computer Science 2023-07-25 Zijie Yue , Miaojing Shi , Shuai Ding

This paper presents an approach to assess the perfusion of visible human tissue from RGB video files. We propose metrics derived from remote photoplethysmography (rPPG) signals to detect whether a tissue is adequately supplied with blood.…

Computer Vision and Pattern Recognition · Computer Science 2022-12-26 Benjamin Kossack , Eric Wisotzky , Peter Eisert , Sebastian P. Schraven , Brigitta Globke , Anna Hilsmann

Unaddressed pain in neonates can lead to adverse effects, including delayed development and slower weight gain, emphasising the need for more objective and reliable pain assessment methods. Hence, automated methods using behavioural and…

Computer Vision and Pattern Recognition · Computer Science 2026-04-29 Ashutosh Dhamaniya , Anup Kumar Gupta , Trishna Saikia , Puneet Gupta

Remote photoplethysmography (rPPG) is a technique for estimating blood volume changes from reflected light without the need for a contact sensor. We present the first examples of presentation attacks in the digital and physical domains on…

Computer Vision and Pattern Recognition · Computer Science 2021-10-25 Jeremy Speth , Nathan Vance , Patrick Flynn , Kevin W. Bowyer , Adam Czajka

Recent studies demonstrated that the average heart rate (HR) can be measured from facial videos based on non-contact remote photoplethysmography (rPPG). However for many medical applications (e.g., atrial fibrillation (AF) detection)…

Computer Vision and Pattern Recognition · Computer Science 2019-08-01 Zitong Yu , Xiaobai Li , Guoying Zhao
‹ Prev 1 2 3 10 Next ›